Genset Generator Controller Generator Control ATS Module Generator Controller
Introduction:
- The Hat is an Automatic Start Control Module designed to automatically start and stop diesel and gas generating sets that include non electronic engines.
- The module also provides excellent engine monitoring and protection features.
Specifications:
Working temp | -25°C ~ +70°C |
Frequency | 50/60Hz |
Case size | 270*190*70mm |
Size | 240*172*57mm(9.45"*6.77"2.25") |
Panel cutout | 220*160mm(8.7"*6.3") |
Weight | 1.0kg |
Features:
- In buit engine diagnostics removes the requirement for service equipment.
- License free PC software.
- Modules help to improve the life cycle of engine starter motors.
- On site module configuration.
- User friendly set-up and button layout.
Characteristics:
- Measure and display 2-way 3 phase Voltage and Frequency
- Over/under voltage, loss of phase, phase sequence wrong, over/under frequency protection function. As default, phase reverse sequence protection and over/under frequency protection are disable; however, users can set the protection function as need.
- Parameters can be set via PC software using SG72 module (USB to LINK) or other converse module.
- The voltage normal delay of 1# or 2# can be set in (0~60) seconds and the Genset start delay can be set in (0~3600) seconds.
- The voltage abnormal delay of 1# or 2# can be set in (0~60) seconds and the Genset stop delay can be set in (0~3600) seconds.
- “1# power priority”, “Auto/Manual”, “No priority” and “2# power priority” can be set via controller front panel.
- Closing output signal can be set as on intervals or as continuous output.
- Applicable for 2 isolated neutral line.
- Auto/Manual mode. In manual mode, ATS transfer can be implemented via panel pushbutton.
- LEDSmounted on front panel can clearly show ATS running status.
- Forced Open input port been designed; When the input port is active, the switch will be Breaking position forcedly (woks for the ATS with Breaking Position).
- AUX.OUTPUT 1 and AUX.OUTPUT 2 can be configured to make it easy to transfer power supply.
- The output contact capacity of 1# and 2# power supply transfer relay (1#CLOSE, 2#CLOSE) is 5A AC250V, passive contact, can be directly used in driving switch to transfer.
- The output contact capacity of Genset start relay (GENS START) is 7A AC250V/7A DC28V, passive N/C contact.
- Suitable for various AC systems (3 phase 4-wires, 2-phase 3-wires and single-phase 2-wire).
- Modular design, retardant ABS plastic shell, pluggable terminal, built-in mounting,compact structure with easy installation.