Note: Battery Liquid not Included During The Shipping !!!
Main technical specifications!!!
Three-phase AC voltage, leakage current, power, phase, frequency, electric energy and phase sequence test, current limit:
0.00 Ma ~ 1200 A, voltage limit: 0.00 V ~ 600 V, power limit: 0.5 W ~ 720 kW, jaw size: 80X80 mm. Equipped with RS232
interface data upload function, data storage 200 groups.
Introduction:
Product Main Function:
Specification:
Function | Measure three-phase AC voltage, leakage current, current, active power, reactive power, apparent power, total power, phase between current and voltage, phase between phase voltage, frequency, electric energy, phase sequence, etc |
Power Supply | 6V DC(LR6×4 alkaline dry batteries, continuous working 12 hours) |
Measurement method | Clamp CT,integration method |
Clamp Size | 80mmx80mm( can clamp Φ80mm wire, or 96mm × 4mm grounding flat steel ) |
Conductor Position | The detected conductor is in the center position of the clamp |
Data Storage | 200 Groups , flash display “FULL” symbol indicate storage full |
RS232 Interface | With RS232 interface, storage data can be uploaded to computer, convenient to data analyze |
Communication cable | RS232 communication cable, length: 1.8M |
Frequency | 50Hz/60Hz Automatic Identification |
Shift | Automatic |
Sampling Rate | 2 times/second |
Line Voltage | Below 600V circuit test |
Display Mode | LCD:128dots×64dots;Display area:43mm×29mm |
Meter Dimension | 275mm(L)×145mm(W)×40mm(H) |
Backlight | Yes, " * " key control |
Data Hold | Data hold function: "HOLD" symbol display |
Overflow Display | Exceed measure range overflow function: “OL” symbol display |
Automatic Shutdown | 15 minutes after power on, it will power off automatically without any operation to reduce the power consumption |
Battery Voltage | While battery voltage is lower than 5.2V. low battery voltage symbol display, remind to replace the battery |
Weight | 1 kg (include the battery and accessories) |
Working Current | Open backlight 50mA; Close backlight 25mA |
Working Environment | -10℃~40℃;below 80%rh |
Store Environment | -10℃~60℃;below 70%rh |
Insulation Strengh | AC 3700kV/rms(Between iron core and shell) |
Suitable Safety Standard | IEC1010-1、IEC1010-2-032、Pollution 2、CAT Ⅲ(600V) |
Packing:
Package | Outer Package | Carton |
Inner Package | Aluminum case | |
Accessory | Meter | 1 PCS |
Meter Case | 1 PCS | |
Test Wires | 4 PCS (Yellow, green, red, black) | |
Data upload software(CD) | 1 COPY | |
RS232 Special Communication Cable | 1 PCS | |
Manual | 1 PCS | |