| range of product | Harmony XB4 | |
|---|---|---|
| product or component type | Complete emergency switching off push-button Emergency stop push-button | |
| device short name | XB4 | |
| bezel material | Chromium plated metal | |
| fixing collar material | Zamak | |
| mounting diameter | 0.87 in (22 mm) | |
| sale per indivisible quantity | 1 | |
| shape of signaling unit head | Round | |
| type of operator | Trigger action and mechanical latching | |
| head type | Standard | |
| reset | Turn to release | |
| operator profile | Red mushroom Ø 40 mm unmarked | |
| contacts type and composition | 1 NC | |
| contact operation | Slow-break | |
| connections - terminals | Screw clamp terminals: <= 2 x 1.5 mm² with cable end conforming to EN 60947-1 Screw clamp terminals: >= 1 x 0.22 mm² without cable end conforming to EN 60947-1 |
| height | 1.85 in (47 mm) | |
|---|---|---|
| width | 1.57 in (40 mm) | |
| depth | 3.23 in (82 mm) | |
| terminals description ISO n°1 | (21-22)NC | |
| product weight | 0.26 lb(US) (0.118 kg) | |
| resistance to high pressure washer | 1015.26 psi (7000000 Pa) at 131 °F (55 °C),distance: 0.1 m | |
| contacts usage | Standard contacts | |
| positive opening | With positive opening conforming to EN/IEC 60947-5-1 appendix K | |
| operating travel | 0.06 in (1.5 mm) (NC changing electrical state) 0.17 in (4.3 mm) (total travel) | |
| mechanical durability | 300000 cycles | |
| tightening torque | 7.08...10.62 lbf.in (0.8...1.2 N.m) conforming to EN 60947-1 | |
| shape of screw head | Cross head compatible with Philips no 1 screwdriver Cross head compatible with pozidriv No 1 screwdriver Slotted head compatible with flat Ø 4 mm screwdriver Slotted head compatible with flat Ø 5.5 mm screwdriver | |
| contacts material | Silver alloy (Ag/Ni) | |
| short-circuit protection | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 | |
| [Ith] conventional free air thermal current | 10 A conforming to EN/IEC 60947-5-1 | |
| [Ui] rated insulation voltage | 600 V (degree of pollution: 3) conforming to EN 60947-1 | |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-1 | |
| [Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 | |
| electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
| electrical reliability | Λ < 10exp(-6) 5 V 1 mA in clean environment EN/IEC 60947-5-4 Λ < 10exp(-8) 17 V 5 mA in clean environment EN/IEC 60947-5-4 | |
| device presentation | Complete product |