| range of product | Harmony XALD | |
|---|---|---|
| product or component type | Complete control station | |
| device short name | XALD | |
| product destination | For XB5 Ø 22 mm control and signalling units | |
| control station application | Start-Stop function | |
| colour of base of enclosure | Light grey RAL 7035 | |
| colour of cover | Dark grey RAL 7016 | |
| material | Polycarbonate | |
| operator profile | 2 flush push-buttons | |
| operators description | Green ''I'' 1 NO - red ''O'' 1 NC | |
| control station composition | 1 flush push-button green 1 NO I marking 1 flush push-button red 1 NC O marking | |
| marking location | Marking on push-button | |
| contact operation | Slow-break |
| cable entry | 2 knock-outs for cable entry, clamping capacity: 14 mm 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm | |
|---|---|---|
| product weight | 0.51 lb(US) (0.233 kg) | |
| resistance to high pressure washer | 1015.26 psi (7000000 Pa) at 131 °F (55 °C), distance: 0.1 m | |
| colour of marking | Black marking when white caps White marking when green, red or black caps | |
| positive opening | With conforming to EN/IEC 60947-5-1 appendix K | |
| operating travel | 0.06 in (1.5 mm) (NC changing electrical state) 0.1 in (2.6 mm) (NO changing electrical state) 0.17 in (4.3 mm) (total travel) | |
| operating force | 3.5 N (NC changing electrical state) 3.8 N (NO changing electrical state) | |
| mechanical durability | 10000000 cycles | |
| connections - terminals | Screw clamp terminals: <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1 Screw clamp terminals: >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1 | |
| tightening torque | 7.08...10.62 lbf.in (0.8...1.2 N.m) conforming to EN/IEC 60947-1 | |
| shape of screw head | Cross, Philips no 1 Cross, pozidriv No 1 Slotted, flat Ø 4 mm Slotted, flat Ø 5.5 mm | |
| contacts material | Silver alloy (Ag/Ni) | |
| short-circuit protection | 10 A by gG cartridge fuse conforming to EN/IEC 60947-5-1 | |
| [Ith] conventional free air thermal current | 10 A conforming to EN/IEC 60947-5-1 | |
| [Ui] rated insulation voltage | 600 V (degree of pollution: 3) conforming to EN/IEC 60947-1 | |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-1 | |
| [Ie] rated operational current | AC-15, A600: Ue = 120 V Ie = 6 A conforming to EN/IEC 60947-5-1 AC-15, A600: Ue = 240 V Ie = 3 A conforming to EN/IEC 60947-5-1 AC-15, A600: Ue = 600 V Ie = 1.2 A conforming to EN/IEC 60947-5-1 DC-13, Q600: Ue = 125 V Ie = 0.55 A conforming to EN/IEC 60947-5-1 DC-13, Q600: Ue = 250 V Ie = 0.27 A conforming to EN/IEC 60947-5-1 DC-13, Q600: Ue = 600 V Ie = 0.1 A conforming to EN/IEC 60947-5-1 | |
| electrical durability | 1000000 cycles AC-15, 2 A at 230 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles AC-15, 3 A at 120 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles AC-15, 4 A at 24 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles DC-13, 0.2 A at 110 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles DC-13, 0.5 A at 24 V, operating rate: <= 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C | |
| electrical reliability | Λ < 10exp(-6) at 5 V, 1 mA conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V, 5 mA conforming to EN/IEC 60947-5-4 |
| protective treatment | TH | |
|---|---|---|
| ambient air temperature for storage | -40...158 °F (-40...70 °C) | |
| ambient air temperature for operation | -40...158 °F (-40...70 °C) | |
| overvoltage category | Class II conforming to IEC 60536 | |
| IP degree of protection | IP69 IP67 IP66 conforming to IEC 60529 IP69K | |
| NEMA degree of protection | NEMA 13 NEMA 4X | |
| IK degree of protection | IK03 conforming to EN 50102 | |
| standards | EN/IEC 60947-1 EN/IEC 60947-5-1 EN/IEC 60947-5-4 EN/IEC 60947-5-5 JIS C 4520 UL 508 CSA C22.2 No 14 | |
| vibration resistance | 5 gn (12...500 Hz) conforming to IEC 60068-2-6 | |
| shock resistance | 30 gn (duration = 18 ms) half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) half sine wave acceleration conforming to IEC 60068-2-27 |