| Item | Defrost Timer Control |
| Voltage | 120/240V AC |
| Amps | 40 A |
| Contact Type | 1 NO/1 NC |
| Max. On/Off Cycles | 48 Per Day |
| Defrost Time (Minutes) | 15 to 1425 |
| Enclosure Material | No Enclosure |
| Termination Type | Temperature or Pressure, Time |
| Defrost Initiation | Time |
| LED Defrost Indicator | Red |
| Operating Temperature Max | 104°C |
| Applications | Walk-in Refrigeration Cooler/Freezer |
| Electrical Life | 50, 000 operations at full load |
| Minimum On Off Time | 15 min |
| Mounting Options | Bracket |
| Time Initiation | Time |
| On Off Operations | 48 |
| Mechanism Type | Electromechanical |
| Solutions | Refrigeration |
| Operating Temperature Min | -40°C |
| Operating Humidity | 0-95% RH, Non-condensing |
| Motor Load Ratings | 1 HP, 16 FLA, 96 LRA @ 120 VAC; 2 HP, 12 FLA, 72 LRA @ 240 VAC |
| Packaging Applications | Hospitals; Universities; Convenience Stores; Restaurants; Food Storage Warehouses; Food Processing Facilities; Food Service Facilities; Nursing Homes; Medium and Low-Temperature Commercial Refrigeration Systems; Healthcare Facilities |
| Backup Protection Time | None |
| Voltage Selection Type | Auto Voltage |
| Input Voltage Ranges | 120/240 VAC, 60 Hz |
| UL Certification | cULus |
| Time Termination | Temperature; Pressure; Time |
| Market | Commercial |
| Switch Type | 1 SPDT, 1 NC SPST |
| Maximum On Off Time | 23 hours, 45 min |
| Has Captive Trippers CVL | Yes |
| UL Cerfication File Number | #E10694 |
| Resistive Load Ratings | 40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz |
| Has Realtime Clock Face CVL | Yes |
| Application Compatibilities | Commercial Refrigeration; Walk-in Freezer; Walk-in Cooler |
| Resistive Load Ratings Ranges | 40 A, 120-240 VAC |
| Wiring Option | Screw box lug terminals up to one #8 AWG wire |
| Motor Load Ratings Ranges | 1 HP, 16 FLA, 96 LRA @ 120 VAC; 2 HP, 12 FLA, 72 LRA @ 240 VAC |
| Defrost LED Indicator | Red |
| Input Voltage Range(s) | 120/240 VAC, 60 Hz |
| Maximum ON/OFF Times | 23 hours, 45 min |
| Has Real-time Clock Face | Yes |
| Features | Improved relay performance; Automatically detects and adjusts input voltages (120-240 VAC); Moisture resistant conformal-coated board; Time Initiated, Temperature, Pressure or Time Terminated; Captive trippers are field adjustable to 15-minute intervals; No tools required – snaps into alternative enclosures; Moisture resistant conformal-coated board; LED indicators for defrost and refrigeration cycles; Defrost cycles are programmed independently; Real-time clock face for quick, easy and accurate setting |
| Resistive | 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz |
| Minimum ON/OFF Times | 15 min |
| Operating Temperature Min (°F) | -40 |
| Operating Temperature Max (°F) | 104 |
| Has Captive Trippers | Yes |