250' 584-20-3401 16 AWG 1 Pair Type KX ITC/PLTC Armored Thermocouple Cable

Click Thumbnails to Enlarge
 

APPLICATION

• Okonite 584-20-3401 Type KX ITC/PLTC Thermocouple Extension cables are designed for use as instrumentation and process control cables in ITC non-classified or labeled circuits up to 150 volts and 5 amps (750VA) and in Class 2 or 3 Power-Limited circuits where shielding against external interference is required; indoors or outdoors; in wet or dry location with conductor operating temperatures up to 105°C; in cable trays; in raceways; supported by a messenger wire; under raised floors; for direct burial. Suitable Class I, Division 2, Class II, Division 2, or Class III, Division 1 and Zone 2 hazardous locations. The C-L-X sheath provides physical protection against mechanical damage. It may be installed in both exposed and concealed work, secured to supports not greater than 6 feet apart.

CONDUCTOR

• Solid alloys per ANSI MC 96.1.

INSULATION

• Flame-Retardant Okoseal (PVC) per UL 13 and UL 2250

CABLE SHIELD

• Aluminum/Polyester backed tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, same size as the conductor.

INNER JACKET

• Black, flame-retardant, low temperature Okoseal per UL 13 and UL 2250. A rip cord is laid longitudinally under the jacket to facilitate removal.

C-L-X SHEATH

• Close fitting, impervious, continuously welded and corrugated aluminum sheath provides complete protection against moisture, liquids, and gases, has excellent mechanical strength and provides equipment grounding through the sheath.

OUTER JACKET

• Flame-Retardant, low Temperature Okoseal per UL 13 and UL 2250.

CLASSIFICATIONS

• UL Listed as Type ITC/PLTC - Instrumentation Tray Cable/Power Limited Tray Cable, for use in accordance with Article 335 and 722 of the 2023 National Electrical Code. Cables comply with UL 2250 for ITC and UL 13 for PLTC, CL2 and CL3.

FEATURES

• Passes the UL 1581, IEEE 383-1974, & IEEE 1202 vertical tray flame tests.
• Passes the 210,000 BTU/hr vertical tray flame test per ICEA T-29-520.
• Complete pre-packaged, factory-tested wiring system-color coded.
• C-L-X enclosure permits installation in cable tray containing light and power cables without a barrier separator.
• Individual pairs are color coded for simplified hook-up.
• Impervious, continuous sheath excludes moisture, gases and liquids.
• In addition, the aluminum CLX sheath exceeds the equipment grounding requirements of NEC Articles 250.118 and 250.122, and can be used as the equipment grounding conductor
• UL listed for direct burial
• Suitable for low temperature installation of -40°C

PRODUCT SPECIFICATIONS

Size AWG 16
Number of Pairs 1
Inner Jacket Thickness (inches) 0.035
Inner Jacket O.D. (inches) 0.250
C-L-X O.D. (inches) 0.430
Outer Jacket Thickness (inches)
0.050
Overall Diameter (inches) 0.540
Weight (lbs/1000ft) 130