4GHz Handle A powerful analyzer
KC901S + RF Multimeter with vector antenna analysis function
-
New
-
Replace KC901S
-
Frequency range:
Transmission test 9kHz… 4GHz
Reflex testing 9kHz… 4GHz
Audio signal 3Hz… 10MHz
Output level (typical):
+3dBm or 2mW (1MHz - 3GHz)
The built-in RF variable attenuator: 0 - 30dB
0.05-1.5V (audio 3Hz-1MHz)
Input sensitivity:
Better than -107dBm or 1μV (100KHz - 2GHz)
Better than -87dBm or 10μV (2-2.8GHz)
Max input level:
All RF port DC10V, +20dBm
S21 test range (typical):
100dB(1MHz—1GHz,in 100KHz about 60dB)
70dB(1——2GHz)
60dB(2——3GHz)
Resolution:
1Hz Frequency, 0.01dB Level, 0.01°phase, pressure 0.1hPa,0.1m altitude.
The level of uncertainty (typical values, @25°C):
+ 1.5dB (spectrum test, REF=20dBm) ,+ 3dB (spectrum, intensity, pattern)
+ (0.5+0.05L) dB (S21 test, direct calibration, insertion loss L≤60dB)
-3dB (+1dB, loss, vector SOL calibration, -3dB≥RL≥-25dB)
Absolute orientation (more than 90% interval is better than this value):
18dB (3MHz, 15MHz, 2GHz – 3GHz)
20dB (15MHz-2GHz)
The relative orientation (after vector SOL calibration, the calibrator’s
return loss better than 48dB, 90% confidence interval)
45dB (3MHz-2.5GHz)
30dB (1MHz-3MHz, 2.5GHz-3GHz)
20dB (300KHz-1MHz)
Phase relative uncertainty (typically, 3 minutes of preheating, continuous
operation mode)
1°(3MHz - 1GHz)
5°(1GHz - 2.5GHz, 1MHz - 3MHz)
7°(2.5GHz - 3GHz, 300KHz - 1MHz)
Except 20,45,50,100,750,1500MHz ±15kHz
Z and R range: 0-999 ohms
X: ±0-999 ohm
1000-9999 ohm value for reference only
Uncertainty (25-200 ohm range): + (2.5%+5) ohm
Frequency stability:
+ 1ppm/year@25 C
Barometer
Pressure range 300-1100hPa
Pressure uncertainty 3hPa (0~45°C)
The altitude range -100 - 9000m
Measuring speed
2ms/, scanning a screen about 1 second (slow, 450pt)
The instrument can be set more speed, but the error increases. The user can
according to the demand for speed and accuracy demand of weigh options.
Power voltage:
11.5V…… 32V (external power supply); 6.5…… 8.4V (battery)
105V…… 230V, 50/60Hz (DC adapter input)
Battery life (filled with batteries, typical values, @15°C):
7 hours (intensity, spectrum, signal source);
5 hours (S21 or S11, including the insertion loss testing)
20 hours (STOP state, the brightness of the display screen 10%)
Temperature and humidity range allows work:
-20-65°C (external power supply, battery power supply in the range depends
on temperature of the battery characteristics)
10%-90%R.H., no condensation
Size:
200 * 114 * 46mm (length * width * thickness)
Quality (including battery):
Net weight of host machine: less than 1.2kg
Packing: total quality about 2.0kg
-
KC901S+ 4GHz Handheld Network Analyzer
KC901S+ is a multipurpose RF instrument integrating a VNA (vector network
analyzer), spectrum analyzer, field strength meter, and an extra
low-frequency signal source. It can do complete single port vector
measurement and 2-ports simple vector network analyzing.
The differences between the KC901S+ and the KC901S
KC901S+ inherited the advantages of KC901S, and made great improvements.
The frequency range of the KC901S+ from 9kHz to 4GHz.
Main Features
Vector network analyzing up to 4GHz
1Hz frequency step
Good accuracy and anti-interference ability
Abundant functions and easy to carry (Weight less than 1kg)
Main Functions
Transmission measurement (Filter adjustments, measuring amplifiers,
verifying directivity of antennas)
Reflection measurement (Impedance matching network adjustment, antenna
feeding system quality evaluation)
RF source plus an extra audio signal source
Spectrum display and field strength observation (potentially used for
inspecting a radio station’s emission performance, or for searching for the
interference sources)
Recommended Applications
KC901S+ is mainly used for adjusting various RF circuits, such as filters,
amplifiers, splitters, combiners; testing input/output impedance, evaluating
antenna feeding system and detecting equipment’s signal amplitudes at all
level. It can also do filed strength measurement, which is useful during
miscellaneous kinds of search for interference source etc.
Combining intelligence in the community, KC901S+ is the tool to study RF for
students and hobbies. In professional situations, it is used in
communication engineering, antenna manufacturing, daily maintenance of
broadcast, RF circuits development and so on. KC901S+ improves working
efficiency, ease the weight burden and improve working quality.
-
Six basic functions of
KC901S+:
reflection test(S11),
Transmission test(S21),
spectral view(SPEC),
filed intensity(FILED),
RF source (RF SOURCE),
audio frequency source(AF SOURCE).
MODE is used to select function. The equipment shifts between
function menu and function selection menu by using MODE a couple
of times. In most cases, MODE, equal to “HOME”, turns the screen
back to the function menu or function selection menu, so it is
frequently used.
12
The typical application of Reflection Measurement (S11) is
measuring the standing wave of antenna. The right port should be
chosen.
Reflectometer is a kind of vector function with various display
modes, selected in FORMAT menu. In Smith Chart and impedance display,
the second soft menu from the left provides more display modes.
Access: press MODE and then select (S11). (FORMAT) in the soft
menu decides the display mode of measuring result.
The typical application of S21 is measuring amplitude-frequency
characteristics of filter or amplifier and gains of antenna. The
right RF port is to output signal, and the left one is to input.
Access: MODE and then press S21.
Insertion Loss Measurement is a special type of transfer measurement,
characterized by high respond speed. As a result, it applies to the
fine tuning of filter and measurement gains of antenna.
In order to keep consistence with the operating habits of ordinary
receivers, the entry into Insertion Lost Measurement is set in Field
mode.
Access: firstly MODE, and then press FIELD, finally press
Insertion to make “GEN ON” appear.
The typical application of SPEC is monitoring the occupancy and the
interference of band and adjusting circuits producing RF signals
except 45 MHz.KCSA-R100 is connected to find unidentified emission
source.
Access: MODE and then press (SPEC).
FIELD applies to not only measurement field strength coverage but
also searching the amplitude of RF. The port of 901S is capable of
DC isolation so as to externally connect probes to directly search
the signal value of receiver and transmitter. It is necessary to
match impedance and concatenate attenuator when detecting
transmitter. As long as experiences are got, FIELD is used to detect
emission the radio station to find fault in time.
Access: MODE and then press FIELD.
13
RF SOURCE produces a milliwatts signal, with an application of
transmitting weak signals to the air to determine the sensibility
of radio station from a close distance, particularly the sensibility
of relay station. It is ha
ndier to use the small signal for
experienced users. More externally connected attenuators further
develop the applications of signal source.
To some extent, RF Source can adjust the signal level with the help
of a built-in attenuator. The output attenuator plays the role as
an amplitude modulator to carry out ASK. If the output attenuator
has applied to adjusting output range, the used decrement which has
been used is unable to modulate. As a result, the modulation degree
conflicts with the output attenuation. When output attenuation
increases, the modulation degree that can be used reduces.
Access: Press MODE to select NEXT, and then press RF SOURCE in
menu.
AF SOURCE produces a low frequency signal with a typical function
of adjusting the voice-grade channel of electronic equipment.
Because AF SOURCE, with various modulation modes, produces the firm
output of 50MHz, it is used to adjust RF circuits under 50MHz.
In actual, AF SOURCE can be set in a high frequency (but does not
guarantee indices). With the help of its harmonic wave, it can be
used to debug the sensitivity of radio stations.
Access: Press MODE and then select AF SOURCE in menu.
|
|
1.Your
valid phone number is very necessary for the shipping,
otherwise we can't guarantee that the package would
safely arrives.
2. Any Customs tax applied to this package should be
covered by buyers.
3.As has been stated on
the eBay item description, Import duties, taxes and
charges are not included in the item price and shipping
charges. These charges be at the buyer responsibility.
meanwhile the customs tax depend on the buyer local
customs office.
|
|
What in Package:
1 x 901S+ Network analyzer
1 x Power adapter (charger)
1 x User's Manual
|
Contact
Us:
1. We
have
always
been
trying
to
provide
the best
service
and
reliable
products
for
every
customer,
however,
accident
may
happen
sometimes,
please
contact
us to
resolve
any
issue
before
leaving
a
negative
feedback.
2.
Please
contact
us by
"Ask a
question".
Payment
1.
Payment
methods
accepted
: Paypal only.
2.
Payment
must be
received
within 7
business
days of
auction
closing.
Shipping
1. We
ship
your
orders
within
1-2
business
days
after
the
payment
received.
2. Item
shipped
via
Singapore
Post or
HongKong
Post ,
It takes
about
7-14
business
days (USA,CA,AU,UK).others
country
10-20
business
days(Brzil,India,RU),Exact
delivery
time
depends
on
postal
process.
3. If
you do
not
receive
your
item(s)
by 30
business
days,Please
feel
free to
contact
us via
ebay mail system , we will try our very best to resolve any problems with you.
Return
Policy
1.
Return
is
accepted
within
14 days
after
the
buyer's
receiving
the
item.
2. If
this
item is
defective
upon
receipt,
customer
has up
to 14
days
from
date of
receipt
for
exchange
of a new
one.
3.
Unused/unopened
merchandise
will be
fully
credited.
Other
Policies
We are
not
responsible
for any
custom
duty or
import
tax.
If you
need we
write
low
price on
shipping
bill,
pls
leave
message
when you
make
payment
.
All
emails
will be
answered
within
24
hours.
If you
do not
receive
our
reply,
please
kindly
re-sent
your
email
and we
will
reply to
you as
soon as
possible,
Suggest
send
eBay
message
to us,
That is
easy to
find .
|
|
|
|