1.movable part: movable coil type
2:Outlook:See attached picture for details
Needle material: zinc white brass
Needle color: black
3. Direction of needle movement: from left to right
Hand length: 49mm from the end of the needle to the center of the shaft
Hand width: 0.45sh 0.05 mm
4. Material of upper cover: PMOMA
5. Lower cover material: ABS
6. Magnet material: Alnico sintered magnet
7. Frame material: SPCC
8. Enameled wire material: UEW polyurethane copper wire
9. Iridium placement: vertical
10. Wire: two 200mm # 28 wire, a black, - . Article red. They are used to solder the LED
positive/negative electrode. The wire ends need to have 5mm of copper exposed for soldering purposes.
Backlight
Type 1: Two LEDs in series "6V, 20mA", connected to a resistor, 6200 1/2W
Type 2: Two LEDs in series "6V, 20mA", connected to a resistor, 1.3KQ 1/2W
Standard test conditions: temperature 20C*, humidity 70%. If the test result will not be different, it can also be conducted under normal temperature and humidity.
1.Electricity flux degree
The DC current required from the zero scale to the position shown on the scale.
2. Maximum current level The DC current required from the zero scale to the full scale position.
200uA (8%)
3. Internal DC impedance: 7500 or 8%.
4. Insulation impedance
With 500V DC voltage test its insulation value, Iridium shell and electrical circuit insulation impedance
More than 50MΩ.
5. Friction
Iridium on the sense current, and then slowly reduce to zero, the pointer indication position and the error of the center of the zero scale
1mm
6. Zero position
The standard position of the electric cell, the center of the zero scale as the reference, the deviation between the location of the needle and the center of the zero scale
The deviation between the position of the needle and the center of the zero scale is 1mm.
7. Balance
When the Iridium is tilted 90 degrees relative to the standard position, the deviation between the position of the pointer and the center of the zero scale
1mm
8 Needle adhesion
Instantaneously add the full scale current three times the overcurrent, 7 seconds later slowly reduce to the full current of 1/2, at this time, the finger
The needle may stick at the bottom because of the difference in ambient temperature, but the needle should return to the specified range.
Within 1/2 of the full scale
9 Pointer oscillation
The maximum current is added in a linear manner within 5 seconds and then reduced to zero in a linear manner within 5 seconds.
Pointer oscillation without stopping Abnormal conditions such as stopping
Package
1* standing wave meter head radio station power meter transmitter with backlight SWR Watt Meter