Product Overview:

The instrument adopts high frequency voltage doubling circuit, using the latest PWM pulse width modulation technology and the voltage and current double closed loop feedback technology to improve the power supply adjustment rate and load regulation rate, so that the voltage stability is high, the ripple is small. The high quality and portability of DC high voltage generator is realized by using imported high power IGBT device and its driving technology to eliminate the interference of the switch. The selection of imported high-frequency high-voltage rectifier diodes makes the cylinder more compact and lightweight, to enhance the efficiency of the whole machine.It adopts the integral design scheme: cylinder and the host are placed in a box, combined with the latest technology, selection of the new device, small size, high power, light weight, convenient operation, safe and reliable, high quality of power output, is the ideal test instrument for high voltage testing industry. 


Product Features:​ 

1.The output voltage is stable: the high-frequency voltage doubler circuit is applied, and the new PWM pulse width modulation technology and the voltage and current double closed-loop feedback technology are applied to improve the power supply adjustment rate and the load adjustment rate, so that the voltage stability is high and the ripple is small.

2. Comprehensive protection: full protection function, with zero protection, over-voltage protection, over-current protection, breakdown protection, protection circuit uses nanosecond-level special sensor, action fast and reliable, effectively protect personal and equipment safety.

3. 0.75U function: Add intelligent high-precision 0.75U function one-button button, press this button, the voltage and current will automatically jump to the 0.75U state, which is conducive to the test of zinc oxide arrester.

4. zero boost: The boost potentiometer starts from zero, adopts imported multi-turn potentiometer, the boosting process is stable, and the adjustment precision is high.

5. over-voltage setting: over-voltage setting uses digital dialing switch, easy to operate, and has a high setting accuracy.

6. one-piece design: the choice of integrated design, Host and double pressure cylinder is placed in a chassis. The imported high-frequency high-voltage rectifier diode is used to make the double-pressure cylinder small in size, improve the efficiency of the whole machine, and is easy to carry.

7. reliable performance: the key components use high-performance imported components, the pressure roller is coated with special insulating materials, good electrical performance, strong moisture resistance, no leakage.

8. the operation is simple: the instrument interface each function button, the layout is reasonable, the instructions are clear, easy to learn and use.

Technical parameters:​ ​

Specification

60/2

60/3

60/5

60/10

120/2

120/3

120/5

120/10

Rated(kV)
60
60
60

60

120
120

120

120

Rated(mA)
2
3
5

10

2
3

5

10

Rated power(W)
120
180
300

600

240
360

600

1200

Weight(kg)
9
10
Volume(mm3)
465*390*190
565*390*190
Voltage cylinder height(mm)
440
535
Accuracy of output voltage
±(1.0%R±2D)
Accuracy of output current
±(1.0%R±2D)
Ripple factor
≤0.5%
Working mode
Intermittent use, 30 minutes under rated load
Over-load capacity
The no-load voltage can exceed the rated voltage 10% for 10 minutes
The maximum charge current is 1.25 times of the rated current
Power
AC220V±10% 50HZ
Service conditions
Temperature: -10-40ºC
Relative humidity: less than 85% under 25ºC, without moisture
Altitude:less than 1500M