Portable Hwato SDZ-IIb Electronic Acupuncture Stimulator Machine 2 output channel


Hwato SDZ-IIB as electronic needle therapy instrument is popular among hospitals, but it is also a kind of new generation of green therapy health care product, the product by its light, curative effect is distinct from users, is the preferred stock of family care products.


Within the scope of application: widely used in clinical, outside, gynecology, dermatology, ophthalmology, surgery, orthopedics, such as disease hundreds kinds of each system, especially for the week of common diseases such as migraine, trigeminal neuralgia, facial nerve palsy, sciatica, toothache, scapulohumeral periarthritis, tennis elbow, contusion, muscle strain, acute stomach pain, menstrual cramps, constipation, diarrhea, renal colic, biliary colic, acute appendicitis, acute tonsillitis, banded blister all have remarkable curative effect.


Method of use:
1, the output end of the wire inserted into the host
2, connect the output wire on the other side of the skin electrode or filiform needle electrode metal clip.(make sure that the machine has electricity)
3, will the skin electrode affixed to the related points need a massage or filiform needle electrode metal clip in the acupuncture needle on the handle of the needle.
4, turn on the switch.
5, choose waveform patterns, adjust the frequency, setting time, adjust the intensity, starting treatment.
6, shut off the power after using.

Technical parameters:
The power adapter (input AC220V + 50 hz - 22 v + 1 hz output DC9V)
2, the input power: 5.0 VA
3, the output pulse shape, asymmetric bidirectional pulse wave.
4, output pulse way: acoustic output
5, the maximum output power: 0.3 VA (250 Ω load impedance)
6, the output pulse power: 1-100 hz is adjustable
7, work mode:
Continuous wave work modes: continuous
Work discontinuous wave pattern: 15 seconds, stop for 5 seconds
Dilatational wave work mode: thin wave frequency and the ratio of the dense wave frequency is 1;5. Thin wave work 5 seconds, dense wave work for 10 seconds
8, the output current limit: no more than 10 ma (250) Ω load impedance
9, output dc component: 0 ma
10, the output pulse width: 0.2 ms + - 30%
11, size: 150 mm * 74 mm * 32 mm
12, weight: 0.6 KG


Product configuration:
1, the output wire * 2;
2, metal clip * 2 pair (with acupuncture needle);
3, self-adhesive * 2 pair (with acupoint paste, simulated acupuncture massage);
4, alternating current (ac) : external power supply (220 v) also can use direct current (dc); 
5,manual * 1;
6, host * 1