促销8
Product
introduction:
JRL-FS series wind speed instrument is suitable for construction,
meteorological, chemical, power station, industrial and mining enterprises and
other units. A device for instantaneous wind speed of the wind observation.
JRL-FS type wind speed instrument adopts microcomputer chip, intelligent
measurement and control. The only single set alarm scale can be arbitrarily set.
4 window figures show that the display is intuitive and accurate, and with the
working environment temperature detection function. Compared with similar
products, the advantages of high accuracy, convenient observation, stable and
reliable. This machine also increases the early warning output function, in
order to increase the product's function extension, the convenient customer's
use.
Usage
method:
The cable end is first inserted into the air plug socket of the host terminal.
Power cord plug into the 220V socket, flashing lights, at this time for the self
test process, to be 4 windows digital stability, that is, the working state.
Press the set button once, set the wind +0.5 grade, 3-10 grade cycle setting,
when the wind speed is higher than the set level, equipment in a state of alarm,
buzzer sound alarm, a flashing light alarm window. At the same time, the
internal relay status flip. Normally open into a short circuit, normally closed
to open. This function is the extension of the function, can be used for
customers to install other functions. Such as: power, sound and light alarm,
etc.
Product installation:
Host: the host installation installed in the driving room, should choose a
stable and firm position. considering the length of the feed line and the
vibration of the tower crane, the host cannot guarantee in the process of using
loose.
Installation of the sensor: anemometer sensor installed on the upper part of the
cabin, the installation must be guaranteed if installed in a horizontal
position, the tower crane could fall.
Cup wind sensor size: 18 * 18 * 16 cm
Note: collateral 10 m shielded cable and connection host, the length of the
cable can be customized, they need to charge the cost of the cable. by
extension, followed by the recommended medium cut way. continue to pay attention
to the color of the cable should not be wrong. if the rotation clockwise, the
pointer is no indicator of wind speed, counterclockwise to indicate that it is
wrong, they need to be corrected.
The Terminal
Out

In
normal state, A normally closed (i.e. conductive).
B normally open (off)
when the alarm is on, the state of the relay is inverted.
A disconnect.
B in order to guide
Window Display:
Wind: Displays the current scale * level
Set the settings of alarm: Wind *
Wind speed: Indicates the current wind speed * rice / second
Temperature: Display the current temperature working environment * c
Issues
That Need Attention:
1. To check if the product and cable are damaged before use. 220V is normal, do
not have access to 380
2. It is forbidden to install the products in an environment of damp heat, dust,
or flammable and corrosive gases.
3. Disconnect the feed before connecting.
4. The installation is firm, the plug of nutrition is connected firmly, and the
phenomenon of bad contact of the socket is avoided. when the sensor plug is not
connected, the host may sometimes have a state of alarm, that is normal, and the
sensor plug can be inserted in the normal state.
5. The wind cup part refers to the treatment and precision assembly, use the
irreversible installation, please do not arbitrarily.
Parameter:
|
Model Name |
Intelligent Anemometer |
|
Input Voltage |
AC220V ( Not Support
110V ) |
|
Power Consumption |
15W |
|
Texture Of Material |
Aluminum, Brass Nickel Plated Cable Plug |
|
Scale Accuracy |
0.5 |
|
Alarm Settings |
3-10 Level It Can Be Customized According To
Customer Requirements |
|
Wind Display |
0-10 Class |
|
Accuracy |
±5% |
|
Starting Wind Speed |
0.7 M/S |
|
Display Parameters |
Wind Speed And Temperature |
|
Operating Temperature |
-30-65°C |
Package Included:
1 x Intelligent Anemometer
|
|