
FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.
If so, you can bid on this item only if you are an authorized purchaser.
If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
For Woodpecker Dental Endo Motor Root Canal Contra Angle Handpiece Reciprocating
Feature
Endo Motor is a dental instrument used to shape and clean the root canals of teeth during endodontic treatment.
The primary function is to remove the infected pulp tissue, bacteria, and debris from the root canals; they also shape the canals to facilitate the filling and sealing process, which is crucial for the success of the treatment.
This equipment should be operated by qualified or approved personnel. The operator should have specialized application skills and work in accordance with the manual.
<Main Unit>
| Battery Voltage | DC3.7V |
|---|---|
| Battery capacity | 800mAh |
| Charging time | 3 hours approx |
| Weight | 432g |
| Packing size | 195*127*66mm |
<AC Adapter>
| Rated input voltage | AC100-240V 50/60Hz |
|---|---|
| Output voltage | DC 5V/MICRO USB |
| Output current | 1A |
<Operation Conditions>
| Environment temperature | +5°C ~ +40°C |
|---|---|
| Relative humidity | 10%-80%RH |
| Atmospheric pressure | 50~106KPa |
There are 9 built-in memory modes from M1 to M9, which can be configured for various operational requirements.
| Mode | Description |
|---|---|
| Automatic Mode | Continuous forward rotation, automatically reversing when encountering resistance. Restores to forward rotation once resistance is removed. |
| Forward Rotation Mode | Automatically stops when encountering resistance. |
| Forward/Reverse Reciprocating Mode | Continuous alternating forward and reverse rotation. |
| Reverse-Stop Mode | Automatically reverses when encountering resistance and stops working after reversing when no resistance is present. |
| Reverse Rotation Mode | Continuous reverse rotation, operating in torque limit mode. |
Wear appropriate protective glasses during use to prevent debris from flying into your eyes during grinding.
Ensure the device is used in a dry and clean environment. Avoid allowing water or other liquids to enter the device.
Regularly check the charger and power plug. Replace them immediately if damaged.
Do not use a damaged charger or use the device with a loose power socket.
| Item | Quantity |
|---|---|
| Motor Handle | 1 pc |
| Contra Angle | 1 pc |
| LED Light | 2 pcs |
| Charging Base | 1 pc |
| Adaptor + USB Cable | 1 set |
| Operation Manual |
1 pc
|
FDA for Curing Light: 510(K) Number: K192233, Regulation Number: 21 CFR 872.6070, Product Code: EBZ
FDA for Handpiece: 510(K) Number: K181691, Regulation Number: 872.4200, Classification Product Code: EFB, Subsequent Product Code: EGS
FDA for Scaler: 510(K) Number: K163414, Regulation Number: 872.4850, Product Code: ELC
Feedback
IMPORTANT INFORMATION ON OUR POLICY AND FEEDBACK
Shipping
Payment
We accept PayPal payment ONLY, it is easy and safe. Payment should be sent within 7 (SEVEN) days of auction closing. All winning bidders whom won our item, please let me know your contact number after you made the full payment , we need this number to make sure you can receive your item in time, and also for emergency contact consideration.

Returns
Terms of Sale:
Refund or replacement request is available only the requests within 1 week after parcel received & returning the item as the same condition as received. Please contact us to request a return authorization. Your name, auction number, and reason for return should be included in the email. All items returned must contain all original packaging materials.Please repack the item carefully. Items returned will be tested and a new replacement will be shipped to the buyer immediately when found defective. In the event that a suitable replacement is not available then a refund will be issued. Shipping, handling and insurance fees are non refundable. If the item is found non-defective, the item will be sent back to the buyer at buyer's expense. Items returned without RMA number will be refused and returned to the sender. Buyer is responsible for All Return Postage and Shipping Charges. Buyer is responsible for additional shipping costs for items that are returned refused and / or undeliverable. We do not accept any returns without an authorization number on the box or label it is being returned.
Contact us
We will reply all messages within 24 business hours and we are able to give you a quick response during the duty time. If we are off duty, please kindly be patient and give us a little more time, not just leave the neutral or negative feedback without communication. Every problem will be solved ASAP if you contact us!
Our working time
Monday To Friday:
9:00 am --- 12:00am
1:30pm ---6:00pm
(Please Refer to Beijing Time.)
Seller name: Tina
City, State: Beijing, China
Telephone number: 0371-56645662
Copyright©skyseashop Dental Store,All rights reserved