This Test Station is custom built of PSL components to accurately measure and log conversion efficiency of power supplies, converters, inverters, motor drives, and anything that has an AC input or output, and a DC input or output. It was briefly used to test bidirectional Magnum Energy sine-wave inverters, but later was also used to test industrial overhead bay LED lighting drivers. Not only do you get input and output metrics, you get efficiency and distortion and power quality information, including the ability to data log when you are not at the bench. Setup and measurement is fast and easy, and compared to commercial offerings, will save you thousands of dollars. User manual is at https://bl831.als.lbl.gov/~gmeigs/PDF/PQube_Manual_2.1.pdf

Powerside, formerly PSL or Power Standards Lab, is a premier maker of Power quality measurement equipment. 

keywoThe Test Station is comprised of: 

1. PSL PQube-02-0000:

The PQube AC Power Monitor is a 690V, 50/60Hz power monitor for single- and three-phase systems. This power quality monitor records daily, weekly, and monthly trends, and It features time-triggered snapshots, impulse detection, and the frequency event monitoring. The PQube also provides waveforms and RMS graphs of voltage dips, swells, and interruptions and monitors THD, TDD, RMS Flicker, and voltage and current unbalance. The PQube features two analog inputs, two temperature/humidity monitoring channels, and up to 4 relay outputs. The PQube automatically saves data onto a standard SD card, so no software is required. The PQube includes one signal relay. Accuracy is specified at ±0.05% rdg ±0.05% FS typical (10% ~ 150% of nominal). Complete specifications available at https://www.itm.com/product/psl-pqube-02-000-ac-power-monitor

2. PSL PQube CT4 Current Sense module is a pass-through built-in current transformer module:

The PQube CT4 is a 4 channel, 20A rated current sense transformer capability ratiometric measurement so that much higher currents can be measureed. Accuracy is ±0.2% reading ±0.2% full scale (FS) typical (for 10% ~ 120% FS). This unit measures current waveforms, inrush current, unbalance, harmonics, interharmonics, and power/energy (kW, kWh, kVA, kVAh, kVAR, kVARh, tPF)

3. PSL PQube Ethernet ETH1 module adds network connectivity and remote communication to the test station:

  • 10-T Ethernet (10 Mbps), RJ45 connection.
  • IP Addressing: Supports both DHCP (Dynamic Host Configuration Protocol) and Fixed/Static IP configurations.
  • Email Alerts: Automatically emails event notifications with pictures and Excel-compatible data attachments when power disturbances occur.
  • Web Server: Includes a built-in web server to view real-time PQube status, event logs, and trend recordings.

4. DC Shunts:

There are two 1% accurate shunts for measuring DC current, 50A, and 500A, with a connected Linear Technology DC1113A Evaluation Board which is an amplifier which has an output of 33.3mV per volt of input which results in an output of 200mV per amp, rated from 4-60VDC input.

5. Terminal blocks: An array of terminal blocks for both DC and AC connections.

6. DC circuit breakers: both 10A and 50A DC circuit breakers.

7. Delrin baseplate with large handle for easy transporting. 

8. Wall wart power supply to operate PQube.

9. Pqube TH1 - Temp sensor and humidity sensor for ambient or elevated testing - connects directly to PQube main computer.


Size is approx 12x12x8 inches high. Weight is  about 15 lbs.

keywords...
Analyzer, THD, PF correction, substation, lab, satellite, university, electronics, swell dip transient VAC VDC impedance tester meter fluke HP hewlett packard ERS ABB Schneider Electric Dranetz Eaton Janitza BK Kikisui