Specification:
- Model: N1201SA+
- Working frequency: 34.375MHz ~ 2700MHz
- The frequency step by step: 1kHz
- Display: 2.4inch TFT resolution 320 x 240 (QVGA)
- Battery capacity: 2000mAH (7.4Wh)
- Power consumption: <1.5W
- Charging current: 400mA
- Charger port: USB (only act as charger port)
- Automatic shut-down: can be set (it has been open for 5 minutes ~ 60 minutes optional)
- Measurement parameters: resistance, reactance, standing, s11
- Resolution: four significant figures
- Frequency accuracy: < ±3ppm
- Connector: SMA - K
- Measurement range:
Impedance: 0.1ohm ~ 1000ohm (The absolute value of impedance)
Standing: 1.000~65
S11(dB): 0dB ~ -60dB
- Directivity: < 35dB (140MHz ~ 2GHz calibrated), < 30dB (2GHz ~ 2.7GHz)
- Scan points: 280
- Output level: -18dBm
- Work temperature: 0â~40â
- Atmospheric pressure: 860hPa ~ 1060hPa
Caution:
- Interface: The analyzer has four interfaces in total: single point
measurement, scanning function, system information, calibration and
calibration of cable length measurement and characteristic impedance
measurement interface is unique to N120SA+. It will enter the
single-point measurement interface by default when it is powered on. The
setting parameters are automatically saved after the product is powered
off. When the product is powered on again, the settings of the
interface are completely the same as before the power off, which is
convenient to use.
- Switch on/off: press the CTRL key and then turn on/off.
In the power-on state, press and hold the (2S or above) switch on/off
key. After releasing, the analog device will be shut down.
- Charging: Due to the high power consumption of this device, the
battery capacity is also large. The designed charging current limit is
400mA. It takes about 5 hours to fully discharge until the charging is
completed. If the battery is switched on when charging, the overall
current consumption is about 750mA, so in order to be able to charge
normally, please select a mobile phone charger with a current output
capacity of more than 1A for charging. After the analog battery is out
of power, please charge it in time to avoid damaging the battery. If it
is not used for a long time, it is recommended to charge it every 1 year
to avoid battery failure.
- RF interface: The RF interface is SMAK. Since the strength of copper
is relatively lower than that of other metals, please try to protect it
carefully to avoid falling and pulling.