The Nile on eBay
 

Partial Discharge Characteristics in Polymeric Insulating Material

by Yanuar Z. Arief

In order to improve long-term reliability of polymer power cables, it is essential to understand the mechanisms of degradation and breakdown of solid insulation materials such as crosslinked polyethylene (XLPE), ethylene-propylene rubber and its interfacial phenomena. The insulation performance of polymers usually decreases quickly with high voltage application, if partial discharges(PD) occur in voids or defects. Hence, PD detection and diagnosis are one of the most important means to test HV cables. In this work, firstly it was shown the PD characteristics of simulated XLPE/EPR interface of XLPE cable joint containing three kinds of artificial defects namely metal particle, air void, and wet fiber, respectively. Then investigation of aging time dependence of PD characteristics up to breakdown was performed when a needle-like void defect was artificially introduced in practical XLPE cable joint, and the results were compared with those of model samples. Secondly, study was made on ethylene-propylene rubber (EPR) used as power cable insulation with respect to the effects of crosslinking type of EPR and amount of filler content on the insulation properties.

FORMAT
Paperback
LANGUAGE
English
CONDITION
Brand New


Publisher Description

In order to improve long-term reliability of polymer power cables, it is essential to understand the mechanisms of degradation and breakdown of solid insulation materials such as crosslinked polyethylene (XLPE), ethylene-propylene rubber and its interfacial phenomena. The insulation performance of polymers usually decreases quickly with high voltage application, if partial discharges(PD) occur in voids or defects. Hence, PD detection and diagnosis are one of the most important means to test HV cables. In this work, firstly it was shown the PD characteristics of simulated XLPE/EPR interface of XLPE cable joint containing three kinds of artificial defects namely metal particle, air void, and wet fiber, respectively. Then investigation of aging time dependence of PD characteristics up to breakdown was performed when a needle-like void defect was artificially introduced in practical XLPE cable joint, and the results were compared with those of model samples. Secondly, study was made on ethylene-propylene rubber (EPR) used as power cable insulation with respect to the effects of crosslinking type of EPR and amount of filler content on the insulation properties.

Details

ISBN3639181778
Author Yanuar Z. Arief
Short Title PARTIAL DISCHARGE CHARACTERIST
Pages 132
Publisher VDM Verlag
Language English
ISBN-10 3639181778
ISBN-13 9783639181777
Media Book
Format Paperback
Subtitle Experimental Investigation on XLPE Power Cable and XLPE/EPR interfacial phenomena
Year 2011
Publication Date 2011-09-22
UK Release Date 2011-09-22
Imprint VDM Verlag
Country of Publication Germany
Audience General

TheNile_Item_ID:132422410;