The Switch 30A Relay, Higher Load Power And More Stable Performance. The Receiver Adopts Ultra-High Sensitivity To Accept The Module. The Anti-Interference Ability Is Higher Than The Super-Regeneration Module And The Ordinary Super-Heterodyne Module On The Market. The Distance Is Greatly Enhanced! The Back Tinned Tin Output Current Is More Stable, And The Isolation Slot Works Safer And More Reliable.
Features:
The Switch 30A Relay, Higher Load Power And More Stable Performance. The Receiver Adopts Ultra-High Sensitivity To Accept The Module. The Anti-Interference Ability Is Higher Than The Super-Regeneration Module And The Ordinary Super-Heterodyne Module On The Market. The Distance Is Greatly Enhanced! The Back Tinned Tin Output Current Is More Stable, And The Isolation Slot Works Safer And More Reliable.
Specifications:
Product: Single Pump Special Controller Switch
Size: 55*110*35mm
Product Frequency:433MHz
Working Voltage: DC12-48V
Maximum Load: 1200 W
Working Mode: Jog, Inter-Lock, Self-Locking, Delay
Product Operation Instructions
Learning Function
Jogging Mode: Press And Hold The Learning Button For 3 Seconds To Enter The Learning Mode. After The Red Light Stays On, Immediately Press The Remote Control Button. The Indicator Light Will Flash And Turn Off, Indicating That The "Jogging" Mode Learning Is Successful
Interlock Mode: Press And Hold The Learning Button For 3 Seconds To Enter The Learning Mode. After The Red Light Stays On, Immediately Press The Remote Control "A" Button Once To Turn It On, The Red Light Flashes Twice To Keep It On, And Press The Remote Control "B" Button Again To Turn It Off. When The Red Light Flashes Quickly And Goes Out, The "Interlock" Mode Learning Is Successful
Self Locking Mode: Press And Hold The Learning Button Twice To Enter The Learning Mode. After The Red Light Stays On, Immediately Press The Remote Control Button. The Indicator Light Will Flash And Turn Off, Indicating That The "Self-Locking" Mode Learning Is Successful
Manual Function
Press The Button To Turn On The Relay, The Red Light Stays On. Press The Button Again To Turn Off The Relay, The Red Light Stays Off
Delay Function
Delay Of 5 Seconds: Short Press The Learning Button 3 Times, And Immediately Press The Remote Control Button After The Red Light Stays On. The Indicator Light Will Flash And Turn Off, Indicating A "Delay Of 5 Seconds" Mode Learning Success. Delay Of 10 Seconds: Short Press The Learning Button 4 Times, And Immediately Press The Remote Control Button After The Red Light Stays On. The Indicator Light Will Flash And Turn Off, Indicating A "Delay Of 10 Seconds" Mode Learning Success. Delay Of 15 Seconds: Short Press The Learning Button 5 Times, And Immediately Press The Remote Control Button After The Red Light Stays On. The Indicator Light Will Flash And Turn Off, Indicating A "Delay Of 15 Seconds" Mode Learning Success. Delay Of 20 Seconds: Short Press The Learning Button 6 Times, And Immediately Press The Remote Control Button After The Red Light Stays On, Indicating A "Delay Of 20 Seconds" Mode Learning Success
Code Clearing Operation
Press And Hold The Learning Button Indicator Light On The Control Board For A Long Time, Wait For 6 Seconds For The Indicator Light To Turn Off, And Release The Learning Button To Indicate Successful Code Clearing
Package Included:
1pcs Remote control
1pcs Receiver