Brand New TES-3079K 3 Three Phase Multifunction Digital Power Clamp Meter Tester

 

1.Introduction:
FEATURES:

HVAC Application

  • Check current draw in motors and compressors.
  • Use MAX/MIN/Rescording in the temperature mode to assess efficiency.
  • Test run/start capacitors.
  • Confirm low voltage control signals.
  • Measure flame safeguard device current draw.
  • Confirm power sources.
  • Analyze temperature and voltage or current data with the aid of the time stamp.
  • Insulation test up to 100M Ω.

 

Electrical Application

  • Check for energized circuits and balance loads.
  • 1 Φ /3 Φ (3P3W/3P4W)Power analyzer.
  • Evaluate electrical contacts.
  • Capture motor in-rush current readings.
  • Determine peak power demand periods.
  • Verify line voltage stability.
  • Monitor motors and other loads for excess heat.
  • Check motor run/start capacitor values.

 

2.Specification:

 

SPECIFICATION:
AC Voltage (50Hz to 400 Hz):Trms.
Range
Resolution
Accuracy
Sensitivity
Overload Protection
999.99 mV
0.1mV

±1% ± 0dgts(50,60Hz)

±2%±20dgts(40~100Hz)

2.0mV
600V
9.999 V
1mV
0.020V
99.99V
10mV

±1% ± 20dgts(50,60Hz)

±2% ±20dgts(40~400Hz)
0.20V
600.0V
100mV
2V
Input impedancel:3MΩ.
DC Voltage.
Range
Resolution
Accuracy
Sensitivity
Overload Protection
999.99 mV
0.1mV

±1.0% ± 20dgts

2.0mV
600V
9.999 V
1mV
0.020V
99.99V
10mV
0.20V
600.0V
100mV
2V
Input impedancel:3MΩ. 
 
Resistance (Continuity <40 Ω on the 999.9Ω range).
Range
Resolution
Accuracy
Overload Protection
999.99 Ω
100mΩ

1% ± 10dgts

600V
9.999KΩ
99.99KΩ
10Ω
600.0KΩ
100Ω
M Ω.
Range
Resolution
Accuracy
Overload Protection
9.999 MΩ
1KΩ

5% ± 10dgts

600V
99.99 MΩ
10KΩ
1 Φ/3 Φ Phase Angle:(50Hz,60Hz).
Range
Resolution
Accuracy
Overload Protection
-60 ° ~ 0 ° ~ +60 °
0.1 °
±6.0 °
ACV >100V,ACA>1
1 Φ/3 Φ KW/hp TRUE Power : (PF>0.5 or Φ<60 °)(1hp=745.7W).
Range
Resolution
Accuracy
Overload Protection
60.00KW(<100A)
10W
± 5 %rdg ± 20dgts(50,60Hz)
600VAC/1000AAC
600.0KW(>100A)
100W
Frequency.
Range
Resolution
Accuracy
Overload Protection
40Hz/1KHz
0.1 Hz
± 0.5 %rdg ±2dgts
ACV >0.2V,ACA>6A
AC Current(50 Hz to 400Hz):Trms.
Range
Resolution
Accuracy
Sensitivity
Overload Protection
99.99A
10mA

±2%±20dgts(50,60Hz)

± 4% ± 20dgts (40~400Hz)

0.10A
1000A
999.9A
100mA
1.0A
μ A Trms:(AC+DC)(Burden Voltage:5mV/ μA).
Range
Resolution
Accuracy
Sensitivity
Overload Protection
99.99 μ A
10nA

±1% ± 20dgts

0.20 μ A
600V
999.9 μ A
100nA
2.0 μ A
Capacitance.
Range
Resolution
Accuracy
Overload Protection
10.000 μF
1nF

1.5% ± 5dgts

600V
100.00 μF
10nF
100.0 μF
100nF
7000 μF
1 μF
2.5%±1 5dgts
Temperature(K-Type ther mocouple).
Range
Resolution
Accuracy
Overload Protection
-50 ℃ to 900 ℃
0.1 ℃
1% ± 1 ℃
30VAC or 60VDC
-58 ℉ to 1000 ℉
0.1 ℉
1%±2 ℉
Diode(Continuity<40mV).
Range
Resolution
Accuracy
Overload Protection
2.000V
1mV
±2%±1dgts
600V
1 Φ/3 Φ Apparent Power.
Range
Resolution
Accuracy
Overload Protection
60.00KVA(<100A)
10VA
± 2.5 %rdg ± 20dgts
600VAC/1000AAC

 

Packing Included: 
 
Main unit,Carrying Case & Manaul. 
 
 
Tue, 07 Nov 2023 06:50:45 GMT 638349654451685963 CD141B8780F7142594ADD557621981AF