Yushi Leeb Hardness Tester Dc Impact Device For Holes Or Inside Of Cylinder
Description
 
D Probe - up to 68 HRC
This is the standard unit for the majority of hardness measurements with a wide measuring range. Impact bodies tend to wear out at the high end of the hardness range.
 
DC Probe - up to 68 HRC
This probe is short and convenient in small places - requires a loading stick.
 
DL Probe - up to 68 HRC
This probe as a more slim front section (Ø 4 x 50 mm), that is used in confined surfaces such as gear wheels.
 
D+15 Probe - up to 68 HRC
This probe has a slim front section (elongated impact body, coil position 15 mm elevated) and is used for measuring grooves or recessed surfaces.
 
C Probe - up to 70 HRC
The C Probe is used on surface hardened, coated thin wall components.
This probe reduced impact energy (≈1/4 of the D Probe Unit).
 
Impact Device G - up to 646 HB
The G Probe is used on heavy, rough, cast and forged work pieces.
This probe has increased impact energy (≈9 x of the D Probe Unit).
 
 
Difference 

Model D/DC/DL Type D+15 Type C Type G Type
Impact Energy 11N/mm 11N/mm 2.7N/mm 90N/mm
Diameter of Spherical Tip 3mm 3mm 3mm 5mm
Diameter of Impact Device 20/20/4mm 20mm 20mm 30mm
Length of Impact Device 148/86/204mm 162mm 139mm 246mm
Max Hardness of Sample : 940/940/950HV 940HV 1000HV 650HB
Min. Thickness of Sample 3mm 3mm 1mm 10mm
Min. Thickness of Layers 0.8mm 0.8mm 0.2mm 1.2mm


Package  including  

An Impact Device
A Connection Cable
A Brush
A Support Ring
 
Mon, 06 Nov 2023 23:36:23 GMT 638349393830161098 CD141B8780F7142594ADD557621981AF