Millivolt Meter Intelligent Digital AC Millivoltmeter 

Voltmeter Frequency Meter


Overview:

This is a general-purpose intelligent digital AC millivoltmeter, which adopts the amplifier - detector working principle and high-grade microcontroller control technology, suitable for measuring frequency 5Hz ~ 3MHz, voltage 100uVrms ~ 400Vrms sine wave RMS voltage. The instrument adopts green LED display, clear reading, good vision, long life. Meanwhile, it has the advantages of high measurement accuracy, fast measurement speed, high input impedance and small frequency response error. The whole machine has low power consumption, small volume, light weight, with automatic/manual measurement function, simultaneously displaying the voltage value and dB/dBm value, as well as the range and channel status, the display is clear and intuitive, easy to use, can be widely used in factories, laboratories, scientific research units, troops and schools, is the voltage measurement and testing of the necessary basic instruments.


The instrument can be equipped with 5Hz~3MHz frequency meter plug-in; it can be used as 5Hz~3MHz frequency meter, which makes the instrument can be used in two ways.


Features :


Parameter :

Name

Technical indicators

Frequency range of measured voltage

5Hz~3MHz

Measured voltage range

100µVrms~400Vrms    

dB measurement range:-80dB~52.04dB       (0dB=1Vrms)

dBm measurement range:-77dBm~54.25dBm   (0dBm=1mW,600Ω)

Voltage measurement method

Manual or automatic

Voltage measurement range

 4mVrms/40mVrms/400mVrms/4Vrms/40Vrms/400rms

Measurement of 1kHz voltage

100Hz~100kHz  ±2% Reading ±8 characters

 

Operating Error

50Hz~500kHz  ±3% Reading ±10characters

 

 

10Hz~2MHz   ±4% Reading ±15characters

 

 

5Hz~3MHz  ±6% Reading ±20 characters

 

Measurement of dB and dBm

Error Reference Voltage Measurement Error

Input resistance

10MΩ

Input capacitance

Not more than 30PF

Noise

0 words when input is short-circuited

Frequency meter (optional)

Frequency measurement range:5Hz~3MHz

Input Characteristics

Minimum input voltage:10mVrms

Maximum Allowable Input Voltage: 400Vrms with attenuation, 400Vrms without attenuation.

Low-pass filter: Cut-off frequency approx. 100kHz; In-band attenuation ≤3dB;Out-of-band attenuation z30dB

Gate time: 100ms

Attenuator: Approx. 100 times

Display digits

5

Time base

Better than 5×10-5 

Coupling mode

AC coupling

Interface

RS232 as standard

External Dimensions

210×80×230(mm)

Weights

2kg


Standard Configuration:

  1. Digital AC Millivolt Meter 1 set
  2. Power cord 1 piece
  3. Instruction manual 1 pc
  4. Test cable Q9-Q9 1 piece
  5. RS232 interface 1 piece
  6. Communication interface installation CD-ROM 1 pc
  7. RS-232 communication cable 1 piece
  8. 0.5A/220V fuse (installed in the socket) 2 pcs.
  9. Certificate of Conformity 1 pc
  10. 1 product warranty card and user file card

Optional Configurations:

  1.  Frequency meter 1 piece
  2. Test cable Q9-Q9 1 piece