0820652

The 0820652 SIT-820 NOVA mV Natural Gas Millivolt remote-ready gas valve with manual variable flame adjustment is a Split-system milli-volt control for use in direct vent Natural Gas fireplaces, stoves, gas logs, and similar appliances with a HI/LO burner adjustment with and manually operated knob. 


This 0820652 Natural Gas Valve is specifically designed for use in direct vent fireplaces. It is a durable and reliable gas valve that is easy to install and maintain and can be controlled with a millivolt wall switch or similar remote control system. 

Features:

  • Compatibility: It is compatible with a wide range of direct vent fireplace gas logs and stove models from different manufacturers.
  • Installation: Ease of use: It is easy to install and maintain and is a direct fit replacement for previous versions of the 0820652 gas valves.
  • Certified: All valves are inspected and tested before certification to help ensure ease of replacements and completed repairs. 
  • Warranty: The replacement gas valve comes with a one-year warranty against manufacturer defects.
  • System-Features: It has various features to meet your specific needs, such as remote control capability, variable flame adjustment, and safety features, such as a pilot safety valve and a thermocouple safety valve.
  • Reliability: Sit valves lead the industry in their durability and reliability, with a gas valve that is built to last.

Specifications:

  • Thermocouple Connection: 11/32 ASA-DNC
  • Gas Type: Natural Gas HI/LO Manual Adjustment
  • Natural Gas Inlet: 3/8 in. NPT
  • Natural Gas Outlet: 3/8 in. NPT
  • Split-system millivolt control natural gas valve for use in vented appliances.
  • HI/LO burner adjustment with manually operated knob
  • Minimum Voltage: 145mV Coil resistance 2.25±0.5
  • Thermo-Electric Unit Hold-in Current: Less than 285Ma
  • Drop-out Current: Greater than 125mA with coil resistance 0.018± 0.003
  • Manual Pressure: set-point 3.5” w.c. ± 0.3
  • Range of Adjustment: 3.5” w.c. -1.6” w.c. Set at 30K btu/hr
  • Maximum Natural Gas Inlet Pressure: 1/2 PSIG
  • Ambient Operating Temperature: 32° to 175° F
  • Maximum @ 1 in. W.C. Pressure Drop: 100,000 BTU per hour
  • Regulation Capacity: 5,000 to 195,000 BTU AP per hour

No returned will be accepted on this parts after the packaging has been opened.

 

 

Warning:

 

Never service a heater while the unit is plugged in, operating or still hot.

Severe burns and electrical shock can occur.

Always check for gas leaks after replacing any gas related parts or products.

Repairs should only be preformed by a licensed mechanical contractor.