COMPANY NAME: Toughened Glass Systems
‘TGS Glass Juliet Balconies’ supplied by ‘Toughened Glass Systems’
Our glass Juliet balcony is constructed using the most superior quality durable toughened glass which conforms to BS EN 12150 and BS EN 14449.Designed to blend seamlessly with your property allowing you to enjoy unobstructed views.
Please note some suppliers may be selling cheaper frameless glass Juliet balconies with lower specification glass that may not be thick enough for the application and less fixings.
Company- Toughened Glass Systems
Technical details:
The calculations below are generated for Horizonal Line Load, Concentrated Load and Uniformly distributed Load are based.
Span of pane between fixings 1700mm wide – 13.5mm toughened laminated glass
Horizontal line load: 0.74 KN/m
Concentrated load: 0.5 KN
Uniformly distributed load: 1.0 KN/m2
Span of pane between fixings: 1700 mm
Width of pane: 1100 mm
Design thickness of loaded pane: 9.28 mm
Allowable stress: 59 N/mm2
Stress in loaded pane: 25.17 N/mm2
Allowable deflection for guarding: 25 mm
Maximum deflection under load: 23.33 mm
Span of pane between fixings 2100mm wide – 17.5mm toughened laminated glass
Horizontal line load: 0.74 KN/m
Concentrated load: 0.5 KN
Uniformly distributed load: 1.0 KN/m2
Span of pane between fixings: 2100 mm
Width of pane: 1100 mm
Design thickness of loaded pane: 12.32 mm
Allowable stress: 59 N/mm2
Stress in loaded pane: 21.79 N/mm2
Allowable deflection for guarding: 25 mm
Maximum deflection under load: 23.21 mm
Span of pane between fixings 2500mm wide – 21.5mm toughened laminated glass
Horizontal line load: 0.74 KN/m
Concentrated load: 0.5 KN
Uniformly distributed load: 1.0 KN/m2
Span of pane between fixings: 2500 mm
Width of pane: 1100 mm
Design thickness of loaded pane: 15.52 mm
Allowable stress: 59 N/mm2
Stress in loaded pane: 19.46 N/mm2
Allowable deflection for guarding: 25 mm
Maximum deflection under load: 23.32 mm
The results do not constitute a warranty of fitness for any particular purpose - actual performance may vary in particular applications. These are generated from approved software.
Fitting
You will need to purchase M10 rods to fix the balcony which are available at most builder’s merchants. The round stand-off brackets we supply with the balcony screw directly onto the M10 rods. M10 rods and 2-part resin will be required if fixing into brick/concrete or M10 rods, nut and washer secured internally if fixing into wood. It is solely your responsibility to provide accurate dimensions, sizes cannot be changed or refunded once manufacturing commences. We can provide simulated loading calculations for the glass. All fixings are supplied with standard 10mm back spacers which allow the glass to be off set from the wall/timber post by 10mm. Bigger back spacers can be purchased at additional cost.
Paypal is accepted
All our glass items are delivered using specialist glazing vehicles. To offer best rates on our products drivers arrive alone and labour would need to be available on site to off load from the vehicle.
We recommend having glass suckers on site for heavy items to support off loading and installation. We would need a mobile number before booking delivery.
A message would be sent to the mobile number provided with a delivery date and time slot within a few working days of placing the order.
All glass items are delivered unpackaged safely secured on a glazing vehicle, this allows customers to inspect all items before accepting delivery.
In the past we use to package items but weeks down the line if items were damaged on site there was no way of establishing if the customer caused the damaged or whether it was in transit.
Since implementing this delivery process our deliveries are much more efficient.
Please note all glass items are made to order and orders cannot be changed or refunded once manufacturing commences unless a faulty item is delivered.