MOST ITEMS CAN BE SHIPPED INTERNATIONALLY EVEN THOUGH EBAY'S SITE MAY SAY OTHERWISE. PLEASE CONTACT US FOR A SHIPPING QUOTE. WE CANNOT SHIP TO AN INTERNATIONAL FREIGHT FORWARDER ON SMALLER PACKAGES.

Compression Techniques Corporation T-STAR 1096A T1/Digital Loop Carrier Test Set with a T-STAR 102 T-Span Power Supply
Comes with a manual and what you see in the pictures. If you don't see it, you probably wont get it.
Specifications are from CTC and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
The unit passes all of the self tests and is guaranteed to work.

The Tester Unit's Serial Number Tag Reads:
Model Number: T-STAR 1096A
Serial Number: 1059
Software Version: 1.4

The Power Supply's Serial Number Tag Reads:
Model Number: T-STAR 102
Serial Number: 126

Description:
The T-STAR 1096A is a lightweight, battery-operated test set optimized for monitoring, testing, and troubleshooting T1 span lines, channel banks, trunk circuits, digital switches and SLC*96/Series 5 systems. It includes T1 line, DS1 bit error performance; and 2-way drop/insert, signaling, supervision, dialing and transmission testing capabilities.

The test set is menu-driven and operated from a simple keyboard with push-button controls grouped  functionally in an easy-to-use arrangement. The operator simply presses a Monitor (in-service) or a Test (out-of-service or drop/insert) key and patches to the circuit under test. Related test setups, framing and line code synchronization occur automatically, with test data appearing on screen immediately.

A data memory facility in the T-STAR includes an Event Logging function to record test results and alarm events over selected time periods. Timed-test results can be reviewed on screen or transferred to a printer for a hardcopy record.

T1/DS1 Interface (East-West) Specifications:
Signal Format: DS1 PCM 1.544 Mbps
Interface Modes: Terminate, DSX Monitor, Bridge, Drop/Insert
DS1 Input:
  Terminate Mode: 100 Ohms, +6 to -40 dBdsx
  DSX Monitor Mode: 100 Ohms, 0 to -30 dBdsx
  Bridge Mode: 1000 Ohms, 0 to -40 dBdsx
  Signal & Alarm Indicators:
    Pulses (W/E): Lights green when DS1 pulses are detected
    FR Loss (W/E): Lights red when 2 of 5 frame bits are lost
    All 1's (W/E): Lights red when all ones signal is detected
    All 0's (W/E): Lights red when more than 15 consecutive 0's are detected
    YEL AIM (W/E): Lights yellow when yellow alarm signal is detected
    Pattern Sync (East Only): Lights green when T-STAR is synchronized with incoming DS1 test pattern (corresponding internal pattern generator must be on)
  DS1 Test Points (0 or +5 VDC TTL Pin Jacks):
    *: Ground
    #1: Bipolar violations (+5 VDC)
    #2: Framing Errors (+5 VDC)
    #3: CRC-6 Errors (+5 VDC)
    #4: Yellow Alarm (+5 VDC)
    #5: Loss of frame synchronization (+5 VDC)
    #6: Loss of signal (+5 VDC)
DS1 Output:
  Impedance: 100 Ohms
  Pulse Amplitude: 6V p-p (DSX-1 compatible)
  Line Equalization (Feet): 0 to 133, 133 to 266, 266 to 399, 399 to 533, 533 to 655
  LBO (Line Buildout): 0, -7.5 & -15 dB
  Clock Sources:
    Recovered: From DS1 input signal
    Internal*: Oscillator, 1.544 MHz
    External*: 3000 Ohms, TTL
    Note *: T-STAR must be set to 100-ohm termination mode
Frame Formats: D4 (with & without signaling), ESF (with & without signaling), SLC96 (with signaling), Unframed, S96II (Optional SLC96 Mode II)
Line Codes: AMI, B8ZS, B7
Network Interface:
  LBO: 0, -7.5, -15 dB
  DC Loop: T1 span simplex power loop
  Connectors: DB-15 and RJ-48C

T1 Line & Signal Measurements Specifications:
DS1 Pulse Measurements:
  Voltage: +3.0 to -40.0 dBdsx
  Level (with all 1's Signal): +19.0 to -18.0 dBm
  Accuracy: ±1 dB
Frequency Measurements:
  Range: 1544000 ±300 Hz (15437000 TO 1544300 Hz)
  Resolution: 1 Hz
  Accuracy: 25 ppm
Frame/Clock Slip Counts: Positive/Negative (WEST Input Ref. to East)
T1 Span Simplex Current: 0 to 200 mA (±10%)

BIT Error Test Functions Specifications:
Test Patterns (Framed/Unframed):
  QRSS: 2E20-1 bits (no more than 14 consecutive zeros)
  Pseudorandom (5 choices): 63, 511, 2047, 2E15-1 & 2E20-1 bits
  Fixed (7 choices): 1:3 (1000), 1:7 (10000000), 1:15 (one followed by 15 zeros), 3 in 24 (F01000100000000000000100) where F is location of framing when inserted), 1:31 (one followed by 31 zeros), All ones, User defined 8-bit pattern
  Yellow Alarm Signals:
    SF: Bit 2 is 0 in each time slot
    ESF: 8 ones followed by 8 zeros repeated in Data Link
  Error Injection (Into Test Pattern):
    Auto (Fixed Rates):
      Logic & BPV Codes: 10E-3 to 10E-8
      Frame Errors: 1:2, 1:5, 1:10, 1:50, and 1:100
      Manual: 1 error at a time (each type)
      APS BPV Range Settings: Standard Bell System & Type 51A
Bit Error Measurements:
  Types of Errors:
  Measurement Formats:
    Standard: Bit Errors, Errored Seconds, Error-Free Seconds, Bit Error Rates
    CCITT G.821 (Logic Only): Severely Errored Seconds, Percent Severely Error Seconds, Degraded Minutes, Percent Degraded Minutes, Unavailable Seconds, Percent Availability, Available Seconds
Test Lengths (for Bit Error Rate Measurements):
  Logic & Bipolar Tests: 10E5, 10E6, 10E7, 10E8 bits, & autoranging
  Frame Tests: 10E3, 10E4, 10E5 bits, & autoranging
  CRC-6 Tests: 10E2, 10E3, 10E4 bits, & autoranging
Test Pattern Sync Modes: Auto & Manual
Timed Tests/Error Logging: Refer to Event Logging

VF Functions (East/West) Specifications:
Channel Formats: D1D (SLC96), D2, D3/D4
Frequency Measurements: 300 to 3900 Hz, +3.1 to -97.0 dBm
VF Tones (0 dBm): 404, 1004, 2804 & 2713 Hz
Idle Test Pattern: PCM Code 01111111
E/M Signaling Access (Bantam Jacks - External Control & Monitoring):
  M Lead Control (A bit): -48 VDC (A bit=1) or ground (A bit=0)
  E Lead Monitoring (A bit): Relay contacts Open (A bit=0) or closed (A bit=1)
Signaling Bits (AB/CD):
  Monitoring Incoming Bits: Single channel (also monitor E lead via E/M jack) or all channels simultaneously
  Control Outgoing Bits: Set each bit to logic 1, 0 or alternating 1/0 (also M lead control via E/M jack) Special FXS loop/ground start emulation
Dial Function:
  Signaling Types: DTMF, MF, DP A&B, & DP SF
  Dialed No. Memory Files: 5 files, 69 characters each
  Dialing Modes: Manual, Auto, Repeat
    Manual: Character sent when key is pressed
    Auto: Phone # entered manually or recalled from memory file & sent each time SEND key is pressed
    Repeat: Phone # entered manually or recalled from memory file. When SEND key is pressed the dialing sequence starts (Off-Hook followed by dial number and a 5-second delay and then On-Hook for 3.3 seconds)
    On-Hook/Off-Hook: Standard E&M & SLC96/Series 5 signaling and FXO emulation

Special Functions Specifications:
Autoconfiguration: Auto syncs to SF, ESF, SLC96 & unframed formats & AMI or B8ZS line codes
Event Logging:
  Alarm Events/Bit Errors: Recorded and date/time stamped as they occur
  Timed Tests: Measurements recorded at end of selected test periods and date/time stamped (tests are repeated until function is turned off)
  Timed Measurements: Logic, BPV, Frame & CRC error performance with DS1 Freq. & Level, or DS1 Freq. & Line Current, or Clock & Frame Slips, or VF cannel Freq. & Level
  Error Formats Reported: Total errors, average error rate (over selected test period), errored seconds, error-free seconds, and CCITT Recommendation G.281 logic error formats
  Timed Test Periods: 1, 5, 15, 30, or 45 minutes - 1, 2, 3, 4, 6, 9, 12, 24 or 48 hours
  Test Results: Reviewed on LCD screen or transferred to external printer
CSU Loopback Codes:
  Standard: 10000 (activate) / 100 (deactivate)
  User Defined: Any combination of ones & zeros up to 8 bits
  CSU Emulation: T-STAR responds to CSU loop up/down codes
RS-232C Serial Port (Printer, ANSI terminal or modem):
  Baud Rates: 300, 600, 1200, 2400, 4800 & 9600
  Word Lengths: 7 or 8 bits
  Parity: Odd, Even, or none
Remote Control (Optional and may not have):
  Interface: DEC VT-52/VT-100 or equivalent ANSI terminal (via RS232C port)
  Control: All tests & setup functions
SLC96 Mode II (Optional and may not have): Adds capability acquiring a time slot for an RT channel unit (drop/insert testing of SLC96 Mode II system)

Power Specifications:
Input Power: 12 VDC (via internal rechargeable battery or 115 VAC-12 VDC Power Adapter supplied with T-Star 1500)
Battery Consumption: 7.0 watts, maximum
  Battery:
    Type: GEL/CELL (frequency cycle use)
    Life: 3-5 Hours (under normal operation)
    Recharging Time: 8 to 12 hours

Physical Characteristics:
Dimensions: 12.5" H x 8.25" W x 5.0" D
Weight: 9 lbs. (with cover & battery)
Operating Temperature: 0 to +50°C
Storage Temperature: -40 to +80°C

For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $20.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.

Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:

(1) Are you the end-user of this item?

(2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.

(3) What is the ultimate country destination?

06/26/06