Introduction
<1>. Working principle: Linear photoelectric isolation.
<2>. Usage: Special place for measuring input signal frequency variation and input waveform.AC DC universal.
<3>. Advantages: Better cost performance,fast response,high precision, good stability,small size, light weight,easy installation.
<4>. Application: Measurement of distortion waveforms such as triangular wave, trapezoidal wave and thyristor adjustable (true RMS output).
Imported components, high integration.The input, output, power and outer shell are isolated, with strong anti-interference ability and high reliability. Full channel configuration,Parameter customizable.




Specifications
|
Parameters |
Installation |
Standard rail+Plane screw fixation |
|
Original side rated current |
10mV;20mV;75mV;0.1V;0.5V;1V;10V;50V;100V; 500V;800V;1000V |
|
|
Original side measurement range |
20mV-1200V |
|
|
Rated output |
4-20mA;0-20mA;0-5V; 0-10V |
|
|
Auxiliary power supply |
DC24V; AC220V |
|
|
Load capacity |
Voltage output:5mA; current output:6V |
|
|
Linearity |
0.1% |
|
|
Accuracy |
0.5% |
|
|
Overload capacity |
Double nominal input,sustainable |
|
|
Temperature drift |
≤500PPM/℃ |
|
|
Band width |
DC |
|
|
Consumption of current |
<25mA+output current |
|
|
Working temperature |
-10℃~+70℃ |
|
|
Storage temperature |
-25℃~+85℃ |
|
|
Response time |
<200mS |
|
|
Isolation pressure resistance |
1kV;3kV/50Hz,1Min |
|
|
Offset Voltage |
≤10mV |
Certificates