DESCRIPTION:

The IGD-03 is a top-of-the-line device that provides comfort and ease of use and is successfully used to measure intraocular pressure using the Maklakov method.
The IGD-03 contactless tonometer of the intraocular pressure  is equipped with new software, which guarantees the accuracy of carried out intraocular pressure measurements.
Due to the application of the improved tip supports, the tonometer has managed to eliminate the influence of eyelid damping and reliably fix the probe relative to the eye during the whole measurement procedure.
The principle of operation of the IGD-03 diathera model indicator is based on the magnetodynamic method of generating a dosed movement impulse to a moving rod which interacts very gently and whithin 1/10 second with the elastic surface of the eye through the eyelid, and subsequent processing of its speed function:

  • Fundamental changes in the methodology.
  • Ease and painless procedure.
  • High reliability of results.
  • Now a single measurement and no difficulties with the vertical!
  • Measurement procedure needs a someones assistance.
The new IGD-03 diathera devices retained all the advantages of measuring IOP through the eyelid in the sclera zone.


Evaluate the benefits of the indicator IGD-03 diathera:
  • A single measurement is sufficient to obtain a reliable digital value (according to Maklakov with a load of 10 g).
  • The measuring rod is always in working position.
  • A slight deviation of the device from the vertical does not reduce the reliability of the results.
  • Devices save time and allow you to examine a larger number of patients.
  • Possibility of application in difficult clinical cases: with contraindications to corneal tonometry, with allergies to anesthetics.
  • There is no risk of patient infection, sterilization is not required, it is enough to carry out disinfection.
  • It is possible to measure IOP both in the patient's "lying" position and in the "sitting" position.
  • There is no need to conduct pachymetry, because. the measurement takes place in the area of ​​the sclera, not the cornea.


The IGD-03 contactless tonometer of the intraocular pressure - Great clinical capabilities:

- Allows you to monitor the effectiveness of medication by performing multiple procedures for measuring intraocular pressure throughout the day;
- Provides the possibility of IOP screening during mass examinations of the population in polyclinics, enterprises, the army or the navy;
- Guarantees the successful measurement of intraocular pressure in "difficult" categories of patients - such as immobilized or elderly people and children;
- The use of the device is recommended when contact tonometry is undesirable or impossible - with allergic reactions, viral infections, dry eye syndrome;
- Provides dynamic control of intraocular pressure under conditions of severe ophthalmology, the course of which is accompanied by changes in the anatomical structure of the eyeball;
- It is an irreplaceable device for corneal IOP-tonometry in case of pathological corneal diseases, laser refractive interventions.


Specifications:
The range of measurements:     5-63 mm Hg.
Measurement error within the range: of 5-26 mm Hg. - Error of measurement within the range: of 5-26 mm Hg +/-2 mm Hg, within the range of more than 26 mm Hg - +/-10 mmHg within the range.
Power Consumption: max. 2 mA
The duration of a single measurement procedure: shall not exceed 1 second
Maximum number of measurements that one battery pack can take: 5000 or more
Supply voltage: 3 V
Guaranteed service life: not less than 5 years
Device dimensions: 176×26×20 mm

Instructions in English!!!



Note: Items cost does NOT include Charges, Taxes and Import Duties. Byuer pays all these fees.

__________________________________________________________________________________________________________________________________________________________________________________


Shipping 

Shipping to European - 5-8 days! 

Shipping in the USA- 15-30 days.

Shipping to Canada, Australia or Asia will take about 15-35 days. 

Shipping  by the registered parcel to Worldwide with track number.