VAT invoice available on request
| Cable Construction | |
| Inner Conductor: | Stranded copper clad steel, 7x0.16 ± 0.008mm |
| Dielectric: | Solid Polyethylene, Ø 1.52mm |
| Braid | Tinned copper, TC0.10±0.008x16x5 |
| Braid Coverage | 90% |
| Outer Jacket | LSZH FireFighter™, Black, Ø 2.60 ± 0.20mm |
| Mechanical and Thermal Characteristics | |
| Operating Temperature | -40˚C up to +85˚C |
| Min. Bending radius for Installation | 50mm |
| Fire Propagation | acc. to IEC 60332-1 |
| Electrical Characteristics | |
| Max. Conductor DC resistance at 20˚C | 330 Ω/km |
| Min. Insulation DC resistance at 20˚C | > 1000 MΩ*km |
| Rated Temperature | 85˚C |
| Rated Voltage | 30V |
| Capacitance | 101 pF/m |
| Velocity ratio | 66% |
| Impedance | 50 ± 2 Ω |
| Attenuation at 20˚C | 10 MHz - 9.80 dB/100m 100 MHz - 31.00 dB/100m 200 MHz - 51.00 dB/100m 400 MHz - 74.00 dB/100m 1000 MHz - 120.00 dB/100m |
| Maximum Power Rating at 20˚C | 10 MHz - 240 W 100 MHz - 68 W 200 MHz - 45 W 400 MHz - 32 W 1000 MHz - 18 W |
| Return Loss | 10 - 300 MHz > 23 dB 300- 1000 MHz > 21 dB |