2.2KW 220VAC Input Series Mini Vector Control Inverter with UL certification, positioned as using the high performance mini product of small power market; product using the leading international vector control algorithm, with excellent product features, compatible with wall and rail installation, and the product volume is smaller. Product widely used in Textile machinery, Food machinery, Plastic machinery, Printing and packaging, Environmental protection equipment, Ceramic equipment, Woodworking equipment, Conveying equipment and so on industries.
Mini structure
Easy maintenance
Various installation ways
Excellent performance
Multi-function and easy to use
We will ship the manual with the unit
| Function | Specification | |
| Power input | Input voltage(V) | 1PH 220V(-15%)~240V 3PH 380V(-15%)~480V |
| Input current(A) | Refer to the rated value | |
| Input frequency(Hz) | 50Hz or 60Hz, allowed range: 47~63Hz | |
| Power output | Output motor capacity(kW) | Refer to the rated value |
| Output current(A) | Refer to the rated value | |
| Output voltage(V) | 0-Input voltage, error<5% | |
| Technical control feature | Control mode | SVPWM, SVC |
| Adjustable-speed ratio | 1:100 | |
| Speed control accuracy | ±0.2%(SVC) | |
| Speed fluctuation | ±0.3%(SVC) | |
| Torque response | ≤20ms(SVC) | |
| Starting torque | 0.5Hz/150%(SVC) | |
| Overload capability | 150% of rated current:1 minute 180% of rated current:10 seconds 200% of rated current:1 second | |
| Running control feature | Frequency setting method | Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting, PID setting, MODBUS communication setting |
| Auto- adjustment of the voltage | Keep a stable voltage automatically when the grid voltage transients | |
| Fault protection | Provide comprehensive fault protection functions: over current, over voltage, under voltage, overheating, phase loss and overload, etc. | |
| Peripheral interface | Analog input | 1(AI2)0~10V/0~20mA and 1(AI3)-10~10V |
| Analog output | 2(AO1, AO2)0~10V/0~20mA | |
| Digital input | 4 common inputs, the Max frequency: 1kHz; 1 high speed input, the Max frequency: 50kHz | |
| Digital output | 1 Y terminal output | |
| Relay output | 2 programmable relay outputs RO1A NO, RO1B NC, RO1C common terminal RO2A NO, RO2B NC, RO2C common terminal Contactor capacity: 3A/AC250V | |
| Others | Mountable method | Wall and rail mountable |
| Braking unit | Embedded | |
| EMI Filter | Optional filter: meet the degree requirement of IEC61800-3 C2, IEC61800-3 C3 | |
| Temperature of the running environment | -10~50℃, if above 40℃, derate 1% for every additional 1℃. | |
| Altitude | <1000m If the sea level is above 1000m, please derate 1% for every additional 100m | |
| Protective degree | IP20 | |
| Safety | Meet the requirement of CE&UL | |
| Cooling | Air-cooling | |
One Year Warranty