Pulse oximeters give an estimated oxygen saturation level value. Several research studies and an FDA 2021 safety communication have found that certain physical traits, including but not limited to darker skin pigmentation and melanin, may make the oxygen level estimated value appear higher than it actually is. Users are strongly recommended to establish a baseline value when healthy and at rest. It is recommended that users consult a licensed healthcare provider or professional on how to interpret user readings based on physical traits or characteristics.
          



           
           
               

ES10D-VET Pulse oximeter


Introduction
The Veterinary Pulse Oximeter adopts Photoelectric Oxyhemoglobin Inspection Technology in accordance with Capacity Pulse Scanning & Recording Technology, which can be used to measure SpO2 and pulse through animal’s tongue or ear. It is applicable for use in family and pet hospital, etc.

Features
●With function menu.
●SpO2 value display.
●PR value and bar graph display.
●Pulse waveform display.
●Screen brightness can be changed.
●Pulse sound indication.
●Review function.
●Clock function.
●Voice prompt for over-limit and low battery.
●Battery status indication.
●Low-voltage indication: low-battery indication appears when the battery voltage is too low to work.
●With SpO2 value and pulse rate value record function, the stored data can be uploaded to computer.
●Real-time data can be transmitted to computer.
●It can be connected with an external oximeter probe.

Performance
●Display mode: 1.77"color screen.
Screen resolution: 128*160.
●SpO2 measurement range: 0 % ~ 100 %(resolution: 1 %).
Accuracy: 70%~100%: ±2%.
0%~69%: unspecified.
●PR measurement range: 30 bpm~250 bpm(resolution: 1 bpm).
Accuracy: ±2 bpm or ±2 %, whichever is greater.
●Accuracy under low perfusion: low perfusion 0.4 %, SpO2 accuracy: ± 4 %; PR accuracy: ± 2 bpm or ± 2 %, whichever is greater.
●Light interference: Under normal and ambient light conditions, the SpO2 deviation ≤ 1%.
●Working current: ≤ 100 mA.
●Working voltage: DC 2.6 V - 3.6 V.
●Power supply: Two AA 1.5V alkaline battery.
●Safety class: internally powered equipment, type BF applied part.

Accessory
●A user manual
●A data line
●A veterinary SpO2 probe

Physical characteristic
Dimension: 110 mm(L) × 60 mm(W) × 24 mm(H)
Weight: about 120 g (including battery)
 