Up for sale is a professional, high-end Dionex ICS-5000 Ion Chromatography System manufactured in 2011 by Dionex Corporation (Sunnyvale, CA). This complete setup includes three standalone modules designed for high-precision analytical testing of anions and cations.
All serial numbers and manufacturer labels are fully intact and legible on the back panels.
Dionex ICS-5000 Single Pump (SP-5 Module)
Part Number (P/N): 072029
Serial Number: 11040447
Power Input: 100-240V, 50/60Hz, 2.0A
Dionex ICS-5000 Detector/Chromatography Module (DC-5)
Part Number (P/N): 072007
Serial Number: 11040807
Features a dual temperature-controlled chamber design to eliminate baseline drift and thermal noise.
Dionex AS-AP Autosampler Module
Model: AS-AP
Date of Mfg: 2011/05/19
Power Input: 100-240V, 50/60Hz, 4.0A
High-capacity sample tray setup for automated, unattended batch runs.
Channel Architecture: Configurable as a standard analytical system ($1\text{ to }4\text{ mm}$ columns), capillary system ($0.2 fluid\text{ to }0.6\text{ mm}$ columns), or an analytical/capillary hybrid setup.
Chemical/Eluent Compatibility: 100% compatible with strong acids and bases (pH range 0–14). The entire fluidic path is completely Metal-Free, constructed from PEEK, PTFE, and other inert materials to eliminate trace metal contamination and withstand aggressive chemical corrosion.
Supported Column Formats: Microbore ($1\text{ mm}$ - $2\text{ mm}$), standard analytical ($4\text{ mm}$), up to capillary formats ($0.25\text{ mm}$).
Software Control: Fully managed via Thermo Scientific / Dionex Chromeleon 6.8 / 7.1 / 7.2 or higher, utilizing native high-speed USB communication protocols.
Pump Type: Dual-piston in-series positive displacement pump, microprocessor-controlled with a direct-drive mechanism that eliminates the need for mechanical pulse dampers.
Operating Flow Rate Range:
Analytical Range: 0.001 to 10.000 mL/min (adjustable in 0.001 mL/min increments).
Capillary Range (if capillary pump pod is installed): 0.001 to 3.000 mL/min.
Flow Rate Precision: $< 0.1\%$ variation.
Maximum Operating Pressure: 3,000 psi ($21\text{ MPa}$) for standard analytical continuous operation.
Pressure Limits: User-configurable high/low pressure safety limits via software for automatic system shutdown protection.
Thermal Zones: Up to 3 independent temperature zones featuring an outstanding stability of $\pm 0.05^\circ\text{C}$.
Column Enclosure Temperature Range: From $10^\circ\text{C}$ to $40^\circ\text{C}$ (utilizing thermoelectric/Peltier cooling) or up to $70^\circ\text{C}$ in high-temperature zones, ensuring an ultra-stable baseline regardless of ambient laboratory temperature fluctuations.
Injection Capacity: Supports electrically actuated, low-dispersion 6-port or 10-port automated injection valves.
Detector Compatibility: Accommodates simultaneous or optional installation of Conductivity Detectors (CD) with thermostated cells, Electrochemical/Amperometric Detectors (ED), or UV-Vis optical flow cells.
Injection Precision:
$< 0.3\%\text{ RSD}$ at conventional analytical injection volumes ($\ge 20\ \mu\text{L}$).
$< 1.0\%\text{ RSD}$ at capillary-level micro-injections ($0.4\ \mu\text{L}$).
Injection Volume Range: Configurable from $0.1\ \mu\text{L}$ up to $5000\ \mu\text{L}$ (depending on the installed sample loop size).
Sample Preservation: Optional internal sample cooling capabilities ($4^\circ\text{C}$ to $40^\circ\text{C}$) to protect biological or thermally sensitive samples from degradation.
Needle Mechanism: High-speed XYZ axis movement with automated internal and external needle rinsing between samples to reduce carryover to less than 0.005%.
Disclaimers:
Shipping and Handling
1. If an item is not marked as Free Shipping; the shipping cost for the lower 48 states of the US will be displayed. Shipping costs to non continental states and territories( i.e. Alaska,Hawaii and Puerto Rico) are priced on a case by case basis.
2. Our default shipping carriers are FedEx and UPS but we can accommodate other requests if needed.
3. Handling time are usually 3 business days unless stated otherwise in ebay listing.
4. Local pickup is available at our facility for your convenience (no charge).
5. International shipping is available. Please contact us for a quote. (Note: Buyers are responsible for taxes, duties, and import charges.)
Warranty Conditions
The Limited Warranty is subject to the following conditions:
1. Warranty conditions are limited to description/operation as noted on ebay listing.
2. We will make a good faith honest effort to best describe condition of unit.
3. Please note that AS-IS items are sold without warranty.
4. We shall not be liable under this warranty if any damage or defect results from:
a. Misuse, abuse, neglect, or improper installation
b. Service or alteration by anyone other than someone from our company
5. Should damage occur during shipping, we request a reasonable time to file an insurance claim.
6. Ebay listing will note who is responsible for any return shipping costs.