Function:
Safety evaluation unit for monitoring machine safety sensors (non-contact safety switches, guard switches, etc.).
Accepts up to 8 sensors via interface modules or 1 directly.
Provides two redundant safety outputs and contactor monitoring (EDM).
Safety Standards:
Performance Level PL d (EN ISO 13849-1).
Category 3 architecture.
SILCL 2 (EN/IEC 62061).
Electrical:
Supply: 24 V DC ±10%.
Power consumption: ~90 mA.
Outputs: Two safety relays, each rated up to 250 VAC / 30 VDC, 3 A, 750 VA / 90 W.
Auxiliary functions: EDM (external device monitoring).
Indicators:
LED status for power, sensor channels, external contactor.
Connections:
Screw terminals for 0.08–2.5 mm² wires.
Direct connection for 1 sensor, or up to 8 via Elobau interface modules (363096, 363098, K30, etc.).
Mechanical / Environmental:
Housing: ~94 × 75 × 25 mm.
Mounting: DIN rail TH35.
Protection: IP40 housing.
Operating temperature: 0…+55 °C.