Manufacturer: CyberPower
Model: CyberPower Smart App LCD UPS 1000VA, 900W, RM, 2U, 120V, Online, Double Conversion
Condition: New batteries, refurbished UPS
Part Number: OL1000RTXL2U
Maximum output: 900W / 1000VA
Typical backup time at half load: 20 minutes (450 Watts)
Typical backup time at full load: 7.4 minutes (900 Watts)
Warranty: 1 year full replacement warranty
CyberPower Smart App LCD UPS 1000VA 900W OL1000RTXL2U Manual
OL1000RTXL2U - CyberPower Smart App LCD UPS 1000VA Specifications:
General:
|
Energy Saving |
ECO Mode Efficiency >94% |
|
Energy Star Certified |
Yes |
|
UPS Topology |
Online Double Conversion |
Input:
|
Circuit Breaker |
15 A |
||
|
Cold Start |
Yes |
||
|
Cord Length |
10 ft (3.0 m) |
||
|
Input Frequency Range |
40 Hz – 70 Hz |
||
|
Input Plug Type |
|
||
|
Input Power Factor |
0.99 |
||
|
Input Voltage Range |
60 VAC – 69 VAC for 0–60% Load |
||
|
Nominal Input Voltage |
100 – 125 VAC |
Output:
|
Bypass |
Internal Bypass (Automatic and Manual) |
||
|
Crest Factor |
3:1 |
||
|
ECO Mode Voltage Regulation |
±10%, ±15% (Configurable) |
||
|
Harmonic Distortion |
< 3% at Linear Load |
||
|
On AC WaveForm |
Sine Wave |
||
|
On Battery Frequency |
50/60 Hz ± 0.25Hz (auto-sensing or configurable) |
||
|
On Battery Waveform |
Sine Wave |
||
|
Outlet Type |
|
||
|
Outlets – Total |
8 |
||
|
Output Power Factor |
0.9 |
||
|
Overload Protection |
Line Mode: 105% ~ 125% Load – 1 min |
||
|
Short Circuit Protection |
UPS Output Cut Off Immediately or Input Fuse / Circuit Breaker Protection |
||
|
Typical Transfer Time |
0 ms |
||
|
USB Charge Port |
No |
||
|
VA |
1000VA |
||
|
Watts |
900W |
Battery:
|
Battery Quantity |
3 |
|
Battery Size |
12V/9Ah |
|
Battery Type |
Sealed Lead-Acid Battery |
|
Extended Battery Module |
BP36V60ART2U |
|
Hot-Swappable |
Yes |
|
Replacement Battery Cartridge |
RB1290X3L |
|
Replacement Battery Cartridge Quantity |
1 |
|
Runtime at Full Load |
7.4 min |
|
Runtime at Half Load |
20 min |
|
Smart Battery Management (SBM) Mode |
Yes |
|
Typical Recharge Time |
4 Hours (0% to 90% charged) |
Surge Protection & Filtering:
|
EMI/RFI Filtration |
Yes |
|
Surge Suppression (Joules) |
1780 J |
|
Phone / Network Protection RJ11/RJ45 |
1-In / 1-Out (Combo) |
Management & Communications:
|
Audible Alarms |
Battery Mode Low Battery Overload UPS Fault |
|
Dry Contacts |
Yes |
|
Emergency Power Off (EPO) Port |
Yes |
|
Expansion Slot |
Yes – with optional RMCARD205 or RELAYIO500 - NOT INCLUDED |
|
HID Compliant USB Port |
Yes |
|
LCD |
Multifunction LCD |
|
LED Indicators |
Power On (White) |
|
Management Cable |
USB Cable |
|
Removable LCD Control Panel Option |
Yes – Requires DB26 cable (not included) |
|
Rotatable LCD Control Panel Option |
Yes |
|
Serial Port |
1 Serial |
|
Software (Free Download) |
PowerPanel® Business |
|
Upgradeable firmware |
Yes |
Physical:
|
Color |
Black
|
|
Form Factor |
Rack/Tower
|
|
Material of Construction |
Metal |
|
Mounting Hardware |
Yes |
|
Rack Height |
2U |
|
Physical Dimensions – (WxHxD) (in) |
17 x 3.5 x 16.9 (in) |
|
Physical Weight (lb) |
39.6 |
Environmental:
|
Audible noise at 1m from surface of unit |
38 dBA to 55 dBA (0 to 100% load)
|
|
ECO Mode Thermal Dissipation |
108 BTU/hr |
|
Online Thermal Dissipation |
274 BTU/hr |
|
Operating Elevation |
0 – 10000 ft (0 – 3048 m) |
|
Operating Relative Humidity |
0 – 90 % (non-condensing) |
|
Operating Temperature |
32 – 104 °F (0 – 40 °C) |
|
Storage Elevation |
0 – 50000 ft (0 – 15239 m) |
|
Storage Relative Humidity |
0 – 95% (non-condensing) |
|
Storage Temperature |
-4 – 113 °F (-20 – 45 °C) |
Certifications:
|
Safety |
UL1778 CSA C22.2 NO.107.3 FCC Part 15 Class B |
|
Environmental |
RoHS Compliant |