Novus TxIsoLoop-1 - Loop Powered Current Isolator (1CH, 4-20mA)

TxIsoLoop-1 and TxIsoLoop-2 simplify your application and avoid undesirable ground loops by providing single and dual loop galvanic isolation — a 4-20mA signal ground loop isolator with output powered directly from the input loop, high accuracy, galvanic isolation, and high reliability. This is the single channel version. The 0/4-20mA input is measured and an identical isolated signal is reproduced at the output. Power is drawn from the 0(4)-20mA input loop, so no auxiliary or external power supply is needed. Recommended for electrical grids where electric potential difference is a major risk, the TxIsoLoop galvanic isolator eliminates ground loops, ensuring accuracy and signal safety. This accessory, indispensable for industrial environments, operates with a response time of only 2ms. ✅ 3 Year Manufacturer Warranty — backed by our UK-based technical support Novus TxIsoLoop Datasheet Download Novus TxIsoLoop Manual Download Technical Details Maximum input voltage: 32 Vdc. Voltage drop: <3 Vdc Output signal: 0(4) to 20mA. Max load: 1450Ω Accuracy: 0.2% FS @ 0-60°C / RL=250Ω; 0.3% FS @ -20-75°C / RL=250Ω Operating current: >0.1mA. Overload: <40mA; <32Vdc Response time: 2ms @ RL=250Ω Isolation: 3000Vac / 10s; 240Vac continuous. EMC: EN 61326-1 Ambient temperature range: -20 to +75°C. Humidity: 20-90% RH. Protection: IP40 Wire gauge for connections: 0.14 to 1.5mm². Recommended torque: 0.8Nm. Terminal blocks injected in Polyamide Frequently Asked Questions Do I need a separate power supply?No — power is drawn directly from the 4-20mA input loop, so no auxiliary power supply is needed. What's the difference between this and the TxIsoLoop-2?Channel count — this is the single channel version; the TxIsoLoop-2 provides two isolated channels (or splits one signal into two outputs). Why would I need a loop isolator?To break unwanted ground loops between two pieces of equipment sharing a 4-20mA signal, which can otherwise cause measurement errors or equipment damage on grids with electric potential differences. Industry Applications Ground Loop Elimination — protects signal accuracy on installations with electric potential differences. Sensor-to-PLC Isolation — safely interfaces field instruments with control system inputs. Harsh Electrical Environments — galvanic isolation protects against transients and noise.

Novus TxIsoLoop-1 - Loop Powered Current Isolator (1CH, 4-20mA)

TxIsoLoop-1 and TxIsoLoop-2 simplify your application and avoid undesirable ground loops by providing single and dual loop galvanic isolation — a 4-20mA signal ground loop isolator with output powered directly from the input loop, high accuracy, galvanic isolation, and high reliability. This is the single channel version.

The 0/4-20mA input is measured and an identical isolated signal is reproduced at the output. Power is drawn from the 0(4)-20mA input loop, so no auxiliary or external power supply is needed.

Recommended for electrical grids where electric potential difference is a major risk, the TxIsoLoop galvanic isolator eliminates ground loops, ensuring accuracy and signal safety. This accessory, indispensable for industrial environments, operates with a response time of only 2ms.

3 Year Manufacturer Warranty — backed by our UK-based technical support

Novus TxIsoLoop Datasheet Download

Novus TxIsoLoop Manual Download

Technical Details

Maximum input voltage: 32 Vdc. Voltage drop: <3 Vdc

Output signal: 0(4) to 20mA. Max load: 1450Ω

Accuracy: 0.2% FS @ 0-60°C / RL=250Ω; 0.3% FS @ -20-75°C / RL=250Ω

Operating current: >0.1mA. Overload: <40mA; <32Vdc

Response time: 2ms @ RL=250Ω

Isolation: 3000Vac / 10s; 240Vac continuous. EMC: EN 61326-1

Ambient temperature range: -20 to +75°C. Humidity: 20-90% RH. Protection: IP40

Wire gauge for connections: 0.14 to 1.5mm². Recommended torque: 0.8Nm. Terminal blocks injected in Polyamide

Frequently Asked Questions

Do I need a separate power supply?
No — power is drawn directly from the 4-20mA input loop, so no auxiliary power supply is needed.

What's the difference between this and the TxIsoLoop-2?
Channel count — this is the single channel version; the TxIsoLoop-2 provides two isolated channels (or splits one signal into two outputs).

Why would I need a loop isolator?
To break unwanted ground loops between two pieces of equipment sharing a 4-20mA signal, which can otherwise cause measurement errors or equipment damage on grids with electric potential differences.

Industry Applications

  • Ground Loop Elimination — protects signal accuracy on installations with electric potential differences.
  • Sensor-to-PLC Isolation — safely interfaces field instruments with control system inputs.
  • Harsh Electrical Environments — galvanic isolation protects against transients and noise.

Shipping info

Click the Shipping & Payments tab above the listing description for more info

Click the Shipping & Payments tab above the listing description for more info!

Additional delivery notes

PICK UP OPTION

Sorry, our items are NOT available for pick-up.

PAYMENT


Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart.

We accept payment via All Major Credit Cards (Visa, Mastercard, AMEX, Discover), Google Pay, PayPal, & Apple Pay (on mobile & eBay App).

Thank you for shopping with us on eBay!

Additional Information

No additional information at this time

Ask seller a question

To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.

Ask seller a question

© Production Automation

Click the Shipping & Payments tab above the listing description for more info

Accepted Payment Methods

Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart.

We accept payment via All Major Credit Cards (Visa, Mastercard, AMEX, Discover), Google Pay, PayPal, & Apple Pay (on mobile & eBay App).

Thank you for shopping with us on eBay!

Returns are accepted

Items must be returned within 30 days of the auction ending

Buyer will pay for return shipping.