Novus DigiRail OEE Ethernet | LAN IO Module Modbus (2AI / 6DI / 2DO) MQTT

The DigiRail OEE Ethernet is economical machine monitoring for Overall Equipment Effectiveness (OEE) — hardwired I/O to MQTT or Modbus, passing data to OEE, DCS or SCADA systems, cloud compatible, and doubling as a Modbus TCP-to-RTU or Modbus RTU-to-MQTT gateway. It utilises existing network infrastructure for data acquisition and logging over your LAN. The module contains 6 digital inputs, individually configurable to monitor state (On/Off) or act as counters, plus two analogue inputs and two digital outputs. Initial configuration in Novus NXperience is an extremely quick process. With a small amount of interface wiring the module can begin gathering data in minutes. This can be passed via MQTT to Novus Cloud or similar services, or sent to existing PLC/SCADA systems using the Modbus TCP protocol. Modbus TCP to RTU Gateway This model can be used as a transparent gateway with no mapping of registers required. It's suitable for reading/writing registers on RTU Slaves wired to the RS485 terminals — simply communicate via Modbus TCP and the module automatically translates commands. Gateway Mode is a simple method allowing PLCs with Ethernet to communicate with devices such as temperature controllers, instruments and meters — a great solution for networking field devices which are only equipped with RS485 terminals. ✅ 3 Year Manufacturer Warranty — backed by our UK-based technical support Technical Details Inputs: 6 digital, 2 analogue. Outputs: 2 digital Analogue signals: 0-5V, 0-10V, 0-20mA and 4-20mA. Digital signals: NPN, PNP and dry contact Analogue input impedance: mA: 15Ω + 1.5V, V: 1MΩ Digital input: Logical "0" <0.5V, Logical "1" >3V, max voltage 30V, input impedance 270kΩ, input current @30Vdc typical 0.15mA Max frequency (square wave): dry contact 10Hz, PNP/NPN 3kHz. Min pulse duration: dry contact 50ms, PNP/NPN 150μs Digital outputs: 2 NPN, max switching current 700mA Analogue channel resolution: 15 bits (32000 levels) Communication interface: USB, Ethernet 10/100 Mb/s (IEEE 802.3u), RS485 Software: NXperience Power supply: 10-36 Vdc. Typical consumption 50mA @24V, max 120mA @12V Operating conditions: -20 to 60°C, 5-95% RH non-condensing Battery: CR2032 for internal clock retention. Mounting: DIN rail or screw. Protection: IP20. Enclosure: ABS+PC Frequently Asked Questions Can this connect existing RS485 devices to an Ethernet network?Yes — as a transparent Modbus TCP to RTU gateway, it lets Ethernet-equipped PLCs communicate with RS485-only field devices with no register mapping required. How quickly can I get it collecting data?Initial configuration in Novus NXperience is fast — with minimal interface wiring the module can begin gathering data within minutes. Is there a WiFi version?Yes — see our DigiRail OEE WiFi model if you need wireless rather than wired Ethernet connectivity. Industry Applications OEE & Machine Monitoring — tracks run state and counts for equipment effectiveness reporting. Legacy Device Integration — bridges RS485-only field devices onto an Ethernet/Modbus TCP network. Cloud & MQTT Data Logging — passes hardwired I/O data to Novus Cloud or similar IoT platforms.

Novus DigiRail OEE Ethernet | LAN IO Module Modbus (2AI / 6DI / 2DO) MQTT

The DigiRail OEE Ethernet is economical machine monitoring for Overall Equipment Effectiveness (OEE) — hardwired I/O to MQTT or Modbus, passing data to OEE, DCS or SCADA systems, cloud compatible, and doubling as a Modbus TCP-to-RTU or Modbus RTU-to-MQTT gateway. It utilises existing network infrastructure for data acquisition and logging over your LAN.

The module contains 6 digital inputs, individually configurable to monitor state (On/Off) or act as counters, plus two analogue inputs and two digital outputs.

Initial configuration in Novus NXperience is an extremely quick process. With a small amount of interface wiring the module can begin gathering data in minutes. This can be passed via MQTT to Novus Cloud or similar services, or sent to existing PLC/SCADA systems using the Modbus TCP protocol.

Modbus TCP to RTU Gateway

— simply communicate via Modbus TCP and the module automatically translates commands.

Gateway Mode is a simple method allowing PLCs with Ethernet to communicate with devices such as temperature controllers, instruments and meters — a great solution for networking field devices which are only equipped with RS485 terminals.

3 Year Manufacturer Warranty — backed by our UK-based technical support

Technical Details

Inputs: 6 digital, 2 analogue. Outputs: 2 digital

Analogue signals: 0-5V, 0-10V, 0-20mA and 4-20mA. Digital signals: NPN, PNP and dry contact

Analogue input impedance: mA: 15Ω + 1.5V, V: 1MΩ

Digital input: Logical "0" <0.5V, Logical "1" >3V, max voltage 30V, input impedance 270kΩ, input current @30Vdc typical 0.15mA

Max frequency (square wave): dry contact 10Hz, PNP/NPN 3kHz. Min pulse duration: dry contact 50ms, PNP/NPN 150μs

Digital outputs: 2 NPN, max switching current 700mA

Analogue channel resolution: 15 bits (32000 levels)

Communication interface: USB, Ethernet 10/100 Mb/s (IEEE 802.3u), RS485

Software: NXperience

Power supply: 10-36 Vdc. Typical consumption 50mA @24V, max 120mA @12V

Operating conditions: -20 to 60°C, 5-95% RH non-condensing

Battery: CR2032 for internal clock retention. Mounting: DIN rail or screw. Protection: IP20. Enclosure: ABS+PC

Frequently Asked Questions

Can this connect existing RS485 devices to an Ethernet network?
Yes — as a transparent Modbus TCP to RTU gateway, it lets Ethernet-equipped PLCs communicate with RS485-only field devices with no register mapping required.

How quickly can I get it collecting data?
Initial configuration in Novus NXperience is fast — with minimal interface wiring the module can begin gathering data within minutes.

Is there a WiFi version?
Yes — see our DigiRail OEE WiFi model if you need wireless rather than wired Ethernet connectivity.

Industry Applications

  • OEE & Machine Monitoring — tracks run state and counts for equipment effectiveness reporting.
  • Legacy Device Integration — bridges RS485-only field devices onto an Ethernet/Modbus TCP network.
  • Cloud & MQTT Data Logging — passes hardwired I/O data to Novus Cloud or similar IoT platforms.

Shipping info

Click the Shipping & Payments tab above the listing description for more info

Click the Shipping & Payments tab above the listing description for more info!

Additional delivery notes

PICK UP OPTION

Sorry, our items are NOT available for pick-up.

PAYMENT


Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart.

We accept payment via All Major Credit Cards (Visa, Mastercard, AMEX, Discover), Google Pay, PayPal, & Apple Pay (on mobile & eBay App).

Thank you for shopping with us on eBay!

Additional Information

No additional information at this time

Ask seller a question

To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.

Ask seller a question

© Production Automation

Click the Shipping & Payments tab above the listing description for more info

Accepted Payment Methods

Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart.

We accept payment via All Major Credit Cards (Visa, Mastercard, AMEX, Discover), Google Pay, PayPal, & Apple Pay (on mobile & eBay App).

Thank you for shopping with us on eBay!

Returns are accepted

Items must be returned within 30 days of the auction ending

Buyer will pay for return shipping.