Agilent 1260 Infinity II Binary Pump G7112B

The binary pump comprises two identical pumps integrated into one housing. Binary gradients are created by high-pressure mixing. A built-in degasser is available for applications that require best flow stability, especially at low flow rates, for maximum detector sensitivity. Pulse damper and mixer can be bypassed for low flowrate applications or whenever a minimal transient volume is desirable. Typical applications are high throughput methods with fast gradients on high resolution 2.1 mm columns. The pump is capable of delivering flow in the range of 0.1 – 5 mL/min against up to 600 bar. A solvent selection valve (optional) allows to form binary mixtures (isocratic or gradient) from one of two solvents per channel. Active seal wash (optional) is available for use with concentrated buffer solutions.
Type                                                                  Specification                                         Comments        
Hydraulic system                                  Two dual piston in series pumps with 
                                                             servo-controlled variable stroke drive, 
                                                             power transmission by gears and ball 
                                                             screws, floating pistons 

Designed for use with                          Intuitive User Interface, Automated 
 Agilent InfinityLab Assist                     Workflows, Predictive Maintenance & Assisted 
                                                             Troubleshooting 

Flow range                                          settable: 0.001 – 5 mL/min                                Set points in 0.001 mL/min increments
                                                            recommended: 0.05 – 5.0 mL/min  

Flow precision                                    ≤ 0.07 % RSD or < 0.02 min SD, whichever       Based on retention time at 
                                                            is greater                                                             constant temperature 

Flow accuracy                                    ± 1 % or 10 µL/min, whichever is greater            Pumping degassed H2O at 
                                                                                                                                      10 MPa (100 bar, 1450 psi) 

Pressure operating range                  Up to 60 MPa (600 bar, 8702 psi) up to 
                                                            5 mL/min 

Pressure pulsation                                < 2 % amplitude (typically < 1.3 %), or 
                                                             < 0.3 MPa (3 bar, 44 psi), whichever is 
                                                              greater 

                                                              Low delay volume configuration: < 5 % 
                                                             amplitude (typically < 2 %) 

Compressibility compensation             Pre-defined, based on mobile phase 
                                                             compressibility 

Recommended pH range                     1.0 – 12.5                                                            Solvents with pH < 2.3  should not 
                                                                                                                                         contain acids that attack stainless steel

Gradient formation                            High-pressure binary mixing 

Delay volume                                    Standard delay volume configuration:                    Measured with water at 1 mL/min 
                                                          600 – 900 µL, (includes 400 µL mixer),                   (water/water with tracer)
                                                         dependent on back pressure 

                                                         Low delay volume configuration: 120 µL  

Composition range                            Settable: 0 – 100 % Recommended: 
                                                          1 – 99 % or 5 µL/min per channel, whichever 
                                                           is greater 
Composition precision                      < 0.15 % RSD or < 0.04 min SD, whichever            At 0.2  and 1 mL/min; based on
                                                           is greater                                                              retention time at constant temperature 

Composition accuracy                       ± 0.35 % absolute                                                   At 2 mL/min, at 10 MPa (100 bar, 1450 psi)                                                                                                                                                (water/ water with tracer) 

Integrated degassing unit                  Number of channels: 2 Internal volume 
                                                            per channel: 0.45 mL 

Instrument control                          LC & CE Drivers A.02.14 or above Instrument 
                                                        Control Framework (ICF) A.02.04 or above 
                                                       Lab Advisor software B.02.08 or above InfinityLab 
                                                       Assist (G7180A) with firmware D.07.40 or above
                                                     Instant Pilot (G4208A) with firmware B.02.20 or above