Dental Autoclave Steam Sterilizer Medical sterilization 18 L
 
 
Description:
Chamber capacity:Ø25×D35CM (Ø9.84×D13.78inch)
Inside capacity:18 Liter
Material:Stainless steel #304
Outside Size(L*W*H) :58*39*36 CM
Packing Size(L*W*H) :64*44*36.5CM 
Sterilizer temperature/pressure:121℃/0.12Mpa; 134℃/0.22Mpa
Sterilize time:25Min/6Min
Power:1000W
AC110V/8A
AC220V/4A
SAFETY : Heating-over protection ; safety valve
Safety equipment:
1.Pressure adjustment: adjust the inter pressure, if over standard value
 automatic vent

2. Avoid overheat protect device: when inter temperature overheat, power break electric current automatically.

Temp and Press display :Led several windows
Disinfection principle:Uses the vapor power emissions cold air / 2 times
Caution
1.Before each use, distilled water is better .
2.Do not use any corrosive or chemical water as the disinfection.
3.Do not share the same electricoutllet with other electrical apparetus.
4.Please pay attention to correct voltage and frequency.
5.Connect steam exhaust pipe with the steam vent,before operation.
Packing:
main unit 1pc
Standard accessories:
Tray Rack 1pc
Tray 3pcs(size:26*15*2cm)
Tray removal tong 1pc
Draining Tube 1pc
Intake pipe 1pc
Operation manual 1pc
Power cord  1pc
 
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
 18L Automatic Autoclave Steam Sterilizer Sterilizition Equipment Dry Function

Description:

Voltage:110V

Heater Power: 1000W

Tank capacity: 18L

Inside dimensions: Φ250 x D350mm

Sterilize temperature: 122℃ & 134℃

Sterilize pressure: 0.12Mpa & 0.23Mpa

Sterilize time: 25min & 6min

Drying time: 40min

Tank Material: Stainless steel #304

Machine size (L*W*H): 60 * 39 * 36cm

Packing size (L*W*H): 61 * 53 * 40cm

N.W.: 33KG

G.W.: 35KG

Standard accessories: (Plate * 3PCS; Shelf * 1PCS; Plate Taking tool * 1PC)

Application: For dental, surgery, beauty salon, medical care, laboratory, and so on.

Caution

1.After the completion of disinfection,please to wait for 10 minutes.

Pressure Gauge in red area. Do not rotate handle, open the steam discharge valve firstly.

2.Before each use, must supply water 800ml of distilled water .

3.Please close steam discharge valve before the disinfection.

4.Do not use any corrosive or chemical water as the disinfection.

5.Do not share the same electricoutllet with other electrical apparetus.

6.Please pay attention to correct voltage and frequency.

7.Connect steam exhaust pipe with the steam vent,before operation.

 

 
FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.