Key Features
-
Measures AC and DC current up to 200 A using detachable jaw
-
600 V AC/DC voltage measurement capability
-
Detachable jaw design improves access in tight or crowded wiring
-
Built-in flashlight for working in low-light environments
-
Compact handheld design suitable for use with protective equipment
-
Stable readings in electrically noisy environments
-
Large backlit display with automatic range selection
-
Includes soft carrying case for storage and transport
Measurement / Functions
AC Current (45–400 Hz)
-
Range: 200.0 A
-
Resolution: 0.1 A
-
Accuracy:
-
±(2% + 5 digits) (45–65 Hz)
-
±(2.5% + 5 digits) (65–400 Hz)
-
Crest Factor:
-
2.5 @ 125 A
-
1.55 @ 200 A
-
Add 2% for C.F. > 2
DC Current
-
Range: 200.0 A
-
Resolution: 0.1 A
-
Accuracy: ±(2% + 5 digits)
AC Voltage (45–400 Hz)
-
Range: 600.0 V
-
Resolution: 0.1 V
-
Accuracy: ±(1.5% + 5 digits)
DC Voltage
-
Range: 600.0 V
-
Resolution: 0.1 V
-
Accuracy: ±(1% + 5 digits)
Resistance
-
Range: 600.0 Ω / 6000 Ω
-
Resolution: 0.1 Ω / 1 Ω
-
Accuracy: ±(1% + 5 digits)
General Specifications
-
Dimensions (L × W × H): 225 × 65 × 46 mm
-
Weight: 275 g (including batteries)
-
Jaw opening: 18 mm
-
Detachable jaw cable length: 900 mm
Environmental
-
Operating temperature: -10°C to +50°C
-
Storage temperature: -40°C to +60°C
-
Operating humidity (non-condensing):
-
≤90% RH (10°C to 30°C)
-
≤75% RH (30°C to 40°C)
-
≤45% RH (40°C to 50°C)
-
Operating altitude: 2000 m
-
Storage altitude: 12,000 m
Power
-
Battery type: 2 × AA (NEDA 15A, IEC LR6)
Temperature Coefficient
-
Add 0.1 × specified accuracy / °C (<18°C or >28°C)
Safety / Compliance
-
ANSI/ISA S82.02.01:2004
-
CAN/CSA-C22.2 No. 61010-1-04
-
UL 61010-1:2004
-
EN/IEC 61010-1:2001
-
Measurement Category: CAT III 600 V
-
Pollution Degree 2
Package Includes
-
Coated instruction card
-
Soft carrying case
-
TL75 test leads
-
Magnetic hanging strap
-
Five AA alkaline batteries