Model Name APS-DR1150F-24
 INPUT
 Input voltage 100~240VAC/120~370VDC
 Input frequency 47~63Hz
 Inrush current (Cold start) 110VAC / 4.4A, 230VAC / 2.2A
 OUTPUT
 Output Power 150 W
 Output Voltage 24 VDC
 Hold-up time (Full load@230VAC) 20mS Min.
 Temp. Coefficient ±0.04% / ºC
 Overvoltage protection Auto recovery  
 Overload protection Power limited
 Short circuit protection Auto recovery
 O/P voltage Adjustment +24VDC ± 10%
 Temp. Coefficient ±0.04% / ºC
 Loading (A) (Min. Rated Max) 0A 6.3A 6.3A
 Ripple Noise 150mVp-p   
 Line Reg. ±1% 
 Load Reg. ±2%   
 Efficiency 82%   
 Over voltage Protection 27~30VDC 
 Transient response. (Load change 50% to 100%)
 Voltage deviation 5%
 Recovery time 2mS
 EMC STANDARDS
 EN 55011  Class B
 EN 55022  Class B
 EN 61000-4-2  Level 3
 EN 61000-4-3 Level 3
 EN 61000-4-4  Level 3
 EN 61000-4-5 Level 3
 EN 61000-4-6 Level 3
 EN 61000-4-8 Level 3
 EN 61000-4-11 Level 3
 Environmental
 Operating temperature -20ºC ~ 50ºC ambient, derating each output at 2.5% per degree from 50ºC to 70ºC
 Operating humidity Non-condensing, 5% ~ 95%RH
 Vibration Random vibration, 10Hz ~ 100Hz, 3axise
 MTBF   60,000hrs Min. Per MIL-HDBK-217F, 25ºC GB.
 Certification  CE, UL, CSA