TITAN TPAVT7/Series AIR VELOCITY DUCT FLOW SENSOR TRANSMITTER HVAC AHU BMS
As per pics
International, Scottish highlands + Islands & Ireland please check P&P with me first
Additional information
Chris
(others available )

TheTPAVT/7 air velocity transmitters are designed for applications in ventilation, fan speed control and air velocity control. 

The TPAVT/7 employs a solid state temperature compensated differential pressure cell with microprocessor to provide superior linearity,

measurement accuracy and sensitivity.

The TPAVT/7 is zero calibrated at the touch of a button and provides selectable ranges with outputs of 0-5V or 0-10V with 420mA. 

There is an optional LCD display which can show the selected range and measured values in m/s or fpm and each sensor is provided with 2 metres

of 6mm diameter tube. The TPAVT/7 works in conjunction with any velocity probe.

Specification - TPAVT7/10

Supply     

24Volts AC or DC + 15%

Power Consumption 

10mA plus output load 35mA max

Selectable Ranges   

0-10m/s

0-2000 fpm

Min Operating Measurement 

0.4 m/s (80 fpm)

Unit selection switch 4 

SW4 Off = Display m/s (metres per

sec) SW4 On = Display fpm (feet

per min)

Outputs   

0-5V or 0-10V with 4-20mA.

Output resolution     

1% of output range

Display resolution     

0.1m/s

Total Accuracy

+/-2 m/s typical

Response time (@25 ̊C) 

1.0 second typical

Warm up time 

10 mins on power up

Operating temp 

-20 to + 70 ̊C

Operating Humidity  

0-80% non-condensing

Pressure Overload   

25K Pa

Enclosure Flame retardant 

ABS IP51 (UL94-VO)

The Air Velocity Transmitters are fully compatible with the Titan CCM-VPC BACnet controller.

Connections
Output Link Selection
0-10V or 0-5V
Range selection
DIL Switch
With power on and with
tubes disconnected.
Wait minimum 10 minutes.
Press to zero output
24V
0V
V output (load 3mA)
mA output
(load 100 Ω to 500 Ω)
Features
24V AC or DC Supply
Selectable ranges
Fully Calibrated
Temperature Compensated (-20 ̊C to +70 ̊C)
Zero calibration push button
Outputs 0-5V or 0-10V with 4-20mA. With input protection
Optional LCD display
Display of operating range on LCD (m/s or fpm)
Display of actual velocity on LCD (m/s or fpm)
IP51 housing (IP65 housing optional)
Connections
Output Link Selection
0-10V or 0-5V
Range selection
DIL Switch
With power on and with
tubes disconnected.
Wait minimum 10 minutes.
Press to zero output
24V
0V
V output (load 3mA)
mA output
(load 100 Ω to 500 Ω)
Features
24V AC or DC Supply
Selectable ranges
Fully Calibrated
Temperature Compensated (-20 ̊C to +70 ̊C)
Zero calibration push button
Outputs 0-5V or 0-10V with 4-20mA. With input protection
Optional LCD display
Display of operating range on LCD (m/s or fpm)
Display of actual velocity on LCD (m/s or fpm)
IP51 housing (IP65 housing optional)