• 0.58mm Lead equivalency front protection
  • Pocket: Reinforced Belt, Spacious and Strong
  • Shoulder Pads: Concealed for comfort and durability



Product Description

Waldent Lead Apron + Thyroid Shield

Lead Apron + Thyroid Shield
Effective Results:-
  • 0.5mm Lead equivalency front protection.
  • 0.35mm Lead equivalency (lead apron).
  • BARC certified.
Easy Usage:-

  • Quick & Easy to use.
  • Soft Fabric.

Comfortable:-

  • Weight Adjuster Flexible Back comfortably places more weight on hips, less weight on shoulders.
  • Available with Velcro Straps.
  • Pocket: Reinforced Belt, Spacious and Strong.
  • Shoulder Pads: Concealed for comfort and durability.

Light Weighted:-

  • Length : 98 cm from the shoulder.
  • Breadth : 60 cm.
  • Weight : 3.051 kg.

Waldent Lead Apron & Thyroid Shield Collar & COMBO!

- Dental X-rays are an indispensable tool in diagnosis and monitoring oral conditions.

- It is important that dental lead aprons to be used during such procedure to prevent patient from x - ray exposure.

- A lead apron is a type of protective clothing that acts as a radiation shield.

- Constructed of thin rubber and inside have lead in shape of apron.

- Lead Apron only attenuate radiation,absobs 90 - 95 % of scattered radiation.

- Waldent dental lead apron + thyroid shield offers chest, shoulder, neck and thyroid protection.

- Velcro strap makes this quick and easy to use.

- Hanger clip makes storage a breeze.

Why to wear Lead Apron?

-To Protect from Radiation scatter

- Reduce radiation dose to organs

Precaution : Lead apron should not be folded or thrown on floor as if creass develop, breaks the protective barrier.

A lead apron is a type of protective barrier that acts as a radiation shield. It is constructed of a thin rubber exterior and an interior of lead in the shape of a hospital apron.

Thyroid Sheild Collar is type of apron especially designed to protect Thyroid Gland from exposure of X-Rays during Dental Imaging as it is most vulnerable to X-Ray Exposure.

INDICATIONS:

  • To reduce exposure from X-Rays to vital organs that are potentially exposed to ionizing radiation during dental/medical imaging that uses x-rays

BARC Certified (Certificate available on Request)

Waldent Lead Apron:

  • Weight-2.7kg
  • Length-100cm
  • Width-60cm

Specification Of X-ray Unit Used For Carrying Out The Test : Siemens polydoros - LX with high frequency generator ( max.150 KV, max.800 mA) KV variation : = 1 KV, output variation (COV) : <0.05

Measured Lead Equivalence :0.34 mm at 100 KVp of X-ray beam.

Waldent Thyroid Sheild Collar:

  • Weight-554gm

Specification Of X-ray Unit Used For Carrying Out The Test : Siemens polydoros - LX with high frequency generator ( max.150 KV, max.800 mA) KV variation : = 1 KV, output variation (COV) : <0.05

Measured Lead Equivalence : 0.58 mm at 100 KVp of X-ray beam.