LiCor Odyssey CLx Imaging System ID 18295
Video will open in a new window
Using the eBay App? Paste link into a browser window:
The Li-Cor Odyssey CLx Imaging System gives your lab clear sharp digital results in as little as 6 minutes. By using NIR fluorescence detection, the Licor CLX greatly simplifies your western blot process by eliminating the need to incubate your substrate or wait for the film. This simplification saves you productivity time, conserves water, and reduces the hazardous waste your lab may produce.
The LiCor CLx sets up your data in one digital file that’s ready for immediate analysis and easy record-keeping. The flatbed of this imaging system can scan up to 9 mini-blots, 30 slides, or 6 microplates at once. Near-infrared fluorescence imaging cuts down on the amount of background fluorescence and high sensitivity for your blots. Thanks to the precise laser excitation of the Licor CLx, this fluorescence imaging system gets high signal-to-noise ratios, resulting in images with staggering clarity.
NIR fluorescents are stable steady signals that aren’t affected by time or enzyme kinetics, meaning you can imagine when it’s convenient for you. The dual-channel lasers of this western blot imager also mean you can see multiple targets on the sample blot. The superior data retention of the Odyssey CLx lets you see signals as they really are. The wide linear range and digital formats give you richer, deeper data.
Specifications:
|
Laser/Microscope |
|
|
Image Field Size: |
25 cm × 25 cm |
|
Dynamic Range: |
4 logs (Manual); >6 logs (Auto) |
|
Laser Lifetime: |
40,000 hours typical |
|
700 Channel Laser Source: |
Solid-state diode laser at 685 nm |
|
800 Channel Laser Source: |
Solid-state diode laser at 785 nm |
|
Detectors: |
Silicon avalanche photodiodes |
|
Scanning Speed: |
5 – 40 cm/s |
|
Resolution: |
21 – 337 µm |
|
Focusing Range: |
This microscope is adjustable 0 mm – 4 mm above the scan bed to obtain the best signal-to-noise ratio |
|
Operation Specifications |
|
|
Operating Conditions: |
15-35 °C and dew point no greater than 20 °C |
|
Power Requirements: |
Universal input range is between 100-240 VAC (voltage fluctuations not to exceed 10% of the nominal voltage); 4 Amp maximum; at 120V, 0.5 Amp typical when idle; 50/60 Hz. |
|
Dimensions |
22x25x15″ (29” of clearance needed to open the hood.) |
|
Weight |
70 lbs |
Includes:
- LiCor Odyssey CLx Imaging System | CAT# 9140 | MSRP: $68,750.63
- Windows 10 Notebook Running Image Studio 5.2
- In-Cell Western Assay (ICW) Installed
- System Calibration Report
- Communication Cables
- User Manual
- 120V Power Cord (4A)
- 30-Day Warranty
Disclaimer: Please note any thermometers, gas supply tanks, regulators, or data-loggers seen in our photos is not included unless otherwise noted in the listing. This is our testing tools to show buyer(s) the instrument is working properly up to manufacturer specification and has been tested by our service department. If you see something and have questions please don’t hesitate to ebay message us.