Signal Converter Temperature Transmitter Universal | 0-10V / 4-20mA Out | TxRail

TxRail-USB is an ultra slimline DIN rail mount temperature transmitter or signal converter. It accepts a wide range of industrial signals and is fully configurable via a built-in USB port, using free and simple-to-use software from Novus. Terminal blocks are removable for ease of wiring and fast installation. It allows selection and configuration of input type, measurement range, output type and calibration. The output can be set to either loop powered 4-20mA or 0-10V. Highly accurate and user-friendly, the TxRail-USB performs well from simple to sophisticated measurement applications. ✅ 3 Year Manufacturer Warranty — backed by our UK-based technical support Novus TxRail-USB Datasheet Download Novus TxRail-USB Manual Download Technical Details Universal input accepts Thermocouples J, K, T, E, N, R, S, B, Pt100, Pt1000, NTC, 0-50mV and 0-100mV Configurable measurement range. Sensor break detection per NAMUR Ne43 recommendations Internal cold junction compensation. Pt100/Pt1000 connection for 2, 3 and 4 wires Accuracy (@25°C): typical 0.1% of span for thermocouple, mV, Pt100 and Pt1000 Temperature effect: <±0.16% @25°C Configurable output to 4-20mA loop powered or 0-10V, linearized according to measured temperature Output resolution: 4-20mA output 2µA; 0-10V output 2.5mV Power supply: 10 to 35 Vdc (4-20mA output); 12 to 35 Vdc (0-10Vdc output) Operating temperature: -40 to 85°C Free Windows configuration software via USB micro-B port (USB Class CDC) Dimensions: 99.5 x 114 x 12.5mm Frequently Asked Questions Can I extend transmission distance from a thermocouple?Yes — converting a thermocouple signal to 4-20mA allows much longer transmission distances than a raw thermocouple signal. Can this feed a standard PLC analogue input?Yes — converting a Pt100 or thermocouple to 4-20mA or 0-10V gives compatibility with standard PLC analogue inputs. Can it read a load cell?Yes — it accepts a 0-100mV input, suitable for load cells, and converts it to a standard analogue signal. Industry Applications Long Cable Runs — thermocouple to 4-20mA conversion resists noise over distance. Variable Speed Drive Control — linear speed control driven from a temperature input. Load Cell Measurement — converts a 0-100mV load cell signal to a standard analogue output.

Signal Converter Temperature Transmitter Universal | 0-10V / 4-20mA Out | TxRail

TxRail-USB is an ultra slimline DIN rail mount temperature transmitter or signal converter. It accepts a wide range of industrial signals and is fully configurable via a built-in USB port, using free and simple-to-use software from Novus. Terminal blocks are removable for ease of wiring and fast installation.

It allows selection and configuration of input type, measurement range, output type and calibration. The output can be set to either loop powered 4-20mA or 0-10V. Highly accurate and user-friendly, the TxRail-USB performs well from simple to sophisticated measurement applications.

3 Year Manufacturer Warranty — backed by our UK-based technical support

Novus TxRail-USB Datasheet Download

Novus TxRail-USB Manual Download

Technical Details

Universal input accepts Thermocouples J, K, T, E, N, R, S, B, Pt100, Pt1000, NTC, 0-50mV and 0-100mV

Configurable measurement range. Sensor break detection per NAMUR Ne43 recommendations

Internal cold junction compensation. Pt100/Pt1000 connection for 2, 3 and 4 wires

Accuracy (@25°C): typical 0.1% of span for thermocouple, mV, Pt100 and Pt1000

Temperature effect: <±0.16% @25°C

Configurable output to 4-20mA loop powered or 0-10V, linearized according to measured temperature

Output resolution: 4-20mA output 2µA; 0-10V output 2.5mV

Power supply: 10 to 35 Vdc (4-20mA output); 12 to 35 Vdc (0-10Vdc output)

Operating temperature: -40 to 85°C

Free Windows configuration software via USB micro-B port (USB Class CDC)

Dimensions: 99.5 x 114 x 12.5mm

Frequently Asked Questions

Can I extend transmission distance from a thermocouple?
Yes — converting a thermocouple signal to 4-20mA allows much longer transmission distances than a raw thermocouple signal.

Can this feed a standard PLC analogue input?
Yes — converting a Pt100 or thermocouple to 4-20mA or 0-10V gives compatibility with standard PLC analogue inputs.

Can it read a load cell?
Yes — it accepts a 0-100mV input, suitable for load cells, and converts it to a standard analogue signal.

Industry Applications

  • Long Cable Runs — thermocouple to 4-20mA conversion resists noise over distance.
  • Variable Speed Drive Control — linear speed control driven from a temperature input.
  • Load Cell Measurement — converts a 0-100mV load cell signal to a standard analogue output.

Shipping info

Click the Shipping & Payments tab above the listing description for more info

Click the Shipping & Payments tab above the listing description for more info!

Additional delivery notes

PICK UP OPTION

Sorry, our items are NOT available for pick-up.

PAYMENT


Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart.

We accept payment via All Major Credit Cards (Visa, Mastercard, AMEX, Discover), Google Pay, PayPal, & Apple Pay (on mobile & eBay App).

Thank you for shopping with us on eBay!

Additional Information

No additional information at this time

Ask seller a question

To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.

Ask seller a question

© Production Automation

Click the Shipping & Payments tab above the listing description for more info

Accepted Payment Methods

Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart.

We accept payment via All Major Credit Cards (Visa, Mastercard, AMEX, Discover), Google Pay, PayPal, & Apple Pay (on mobile & eBay App).

Thank you for shopping with us on eBay!

Returns are accepted

Items must be returned within 30 days of the auction ending

Buyer will pay for return shipping.