Digital Panel Meter / Indicator - Novus N1540 USB (2 relays+4-20 mA) - UK Stock

The N1540 is a powerful Universal Indicator used for local indication of a process variable, offering retransmission via 4-20mA signal back to a control device such as a PLC. Large digits give clear visibility, and a basic requirement such as displaying temperature, pressure or speed can be set up quickly, with further options to set alarm limits linked to the two output relays. It reads process sensors and signals from a universal input, doubling as display, scaling and retransmission all in one, and includes an auxiliary 24VDC power supply for direct connection of 2-wire 4-20mA sensors/transducers. It can also function as a standalone controller — for example, by using the switching outputs it's possible to set up the indicator as a level controller. All configuration is carried out using free Novus software and the onboard USB port. N1540 universal process indicator works at a fast sampling rate, ensuring high-performance indication and response to fast-varying processes. With 5 digits for high-resolution variables and a 17mm-high display, N1540 provides a clear view, making it easier for operators to read and diagnose from a distance. Both electronic robustness and anti-flame material enclosure comply with the main world-class approvals for industry devices. ✅ 3 Year Manufacturer Warranty — backed by our UK-based technical support Novus N1540-RT Datasheet Download Novus N1540-RT Manual Download Technical Details Input Signal/Sensor Types Display: LED 7-segment, 5-digit, 17 mm high Input Type: Thermocouples J, K, T, N, R, S, B, E, Pt100, 0-20 mA, 4-20 mA, 0-50 mV, 0-5 Vdc, 0-10 Vdc Accuracy: Thermocouples J, K, T: 0.2% of span ±1°C; N, R, S, B: 0.2% of span ±3°C; Pt100, 0-20mA, 4-20mA, 0-5Vdc, 0-10Vdc: 0.2% of span Sampling Rate: Up to 55 per second. Input resolution: 15 bits Analog Output: 0-20 mA or 4-20 mA (optional), electrically isolated. Output Resolution: 12 bits Alarm: Two alarms. Alarm Types: minimum, maximum, minimum differential, maximum differential, differential out of range, sensor open Auxiliary Power Supply: 24 Vdc. Optional: Analog output (4-20mA or 0-20mA), RS485. Communication: RS-485 Modbus RTU optional Safety: Password protected configuration. Configuration Interface: USB type Mini B (powered) Power Supply: 100 to 240 Vac/dc (±10%) or 12 to 24 Vdc / 24 Vac (-10%/+20%). Maximum Consumption: 6 VA Dimensions: 96 x 48 x 34 mm (1/8 DIN). Front Panel: IP65; Enclosure: IP30. Operating Conditions: 0 to 50°C, 0 to 80% RH up to 30°C. Approvals: CE, UL and cUL Frequently Asked Questions Can this work as a standalone controller, not just a display?Yes — the two switching outputs can be configured with alarm limits, so the indicator can function as a standalone level or process controller as well as a display. Can I retransmit the reading to a PLC?Yes — the optional isolated 4-20mA analogue output retransmits the process value to a PLC or other control device. Is there a 24V version?Yes, see the N1540-RT-24V. Industry Applications Process Instrumentation — local display of temperature, pressure, or speed with retransmission to a PLC. Signal Conversion & Interfacing — universal input accepts most industrial sensor/signal types directly. Level Control — switching outputs can be configured to run the indicator as a standalone level controller.

Digital Panel Meter / Indicator - Novus N1540 USB (2 relays+4-20 mA) - UK Stock

The N1540 is a powerful Universal Indicator uséd for local indication of a process variable, offering retransmission via 4-20mA signal back to a control device such as a PLC. Large digits give clear visibility, and a basic requirement such as displaying temperature, pressure or speed can be set up quickly, with further options to set alarm limits linked to the two output relays. It reads process sensors and signals from a universal input, doubling as display, scaling and retransmission all in one, and includes an auxiliary 24VDC power supply for direct connection of 2-wire 4-20mA sensors/transducers.

It can also function as a standalone controller — for example, by using the switching outputs it's possible to set up the indicator as a level controller. All configuration is carried out using free Novus software and the onboard USB port.

N1540 universal process indicator works at a fast sampling rate, ensuring high-performance indication and response to fast-varying processes. With 5 digits for high-resolution variables and a 17mm-high display, N1540 provides a clear view, making it easier for operators to read and diagnose from a distance. Both electronic robustness and anti-flame material enclosure comply with the main world-class approvals for industry devices.

3 Year Manufacturer Warranty — backed by our UK-based technical support

Novus N1540-RT Datasheet Download

Novus N1540-RT Manual Download

Technical Details

Input Signal/Sensor Types

Display: LED 7-segment, 5-digit, 17 mm high

Input Type: Thermocouples J, K, T, N, R, S, B, E, Pt100, 0-20 mA, 4-20 mA, 0-50 mV, 0-5 Vdc, 0-10 Vdc

Accuracy: Thermocouples J, K, T: 0.2% of span ±1°C; N, R, S, B: 0.2% of span ±3°C; Pt100, 0-20mA, 4-20mA, 0-5Vdc, 0-10Vdc: 0.2% of span

Sampling Rate: Up to 55 per second. Input resolution: 15 bits

Analog Output: 0-20 mA or 4-20 mA (optional), electrically isolated. Output Resolution: 12 bits

Alarm: Two alarms. Alarm Types: minimum, maximum, minimum differential, maximum differential, differential out of range, sensor open

Auxiliary Power Supply: 24 Vdc. Optional: Analog output (4-20mA or 0-20mA), RS485. Communication: RS-485 Modbus RTU optional

Safety: Password protected configuration. Configuration Interface: USB type Mini B (powered)

Power Supply: 100 to 240 Vac/dc (±10%) or 12 to 24 Vdc / 24 Vac (-10%/+20%). Maximum Consumption: 6 VA

Dimensions: 96 x 48 x 34 mm (1/8 DIN). Front Panel: IP65; Enclosure: IP30. Operating Conditions: 0 to 50°C, 0 to 80% RH up to 30°C. Approvals: CE, UL and cUL

Frequently Asked Questions

Can this work as a standalone controller, not just a display?
Yes — the two switching outputs can be configured with alarm limits, so the indicator can function as a standalone level or process controller as well as a display.

Can I retransmit the reading to a PLC?
Yes — the optional isolated 4-20mA analogue output retransmits the process value to a PLC or other control device.

Is there a 24V version?
Yes, see the N1540-RT-24V.

Industry Applications

  • Process Instrumentation — local display of temperature, pressure, or speed with retransmission to a PLC.
  • Signal Conversion & Interfacing — universal input accepts most industrial sensor/signal types directly.
  • Level Control — switching outputs can be configured to run the indicator as a standalone level controller.

Shipping info

Click the Shipping & Payments tab above the listing description for more info

Click the Shipping & Payments tab above the listing description for more info!

Additional delivery notes

PICK UP OPTION

Sorry, our items are NOT available for pick-up.

PAYMENT


Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart.

We accept payment via All Major Credit Cards (Visa, Mastercard, AMEX, Discover), Google Pay, PayPal, & Apple Pay (on mobile & eBay App).

Thank you for shopping with us on eBay!

Additional Information

No additional information at this time

Ask seller a question

To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.

Ask seller a question

© Production Automation

Click the Shipping & Payments tab above the listing description for more info

Accepted Payment Methods

Immediate payment is required upon selecting "Buy It Now" or upon checking out through the cart.

We accept payment via All Major Credit Cards (Visa, Mastercard, AMEX, Discover), Google Pay, PayPal, & Apple Pay (on mobile & eBay App).

Thank you for shopping with us on eBay!

Returns are accepted

Items must be returned within 30 days of the auction ending

Buyer will pay for return shipping.