Technical Specifications:

Description - Kits for Use With RP Series Fans. Installation kit includes:
2 Flex couplings, 1 Dynameter manometer & label, 1 System label, 3 Component labels, and 1 Homeowner information brochure.
Radon Fan Comparison Table:
(air flow in cfm, pressure in inches of water)
| Model | Watts | Max Pressure | Duct Dia | .5 | 1 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 |
| Fantech HP2133 | 14-20 | .84 | 4" | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Fantech HP2190 | 60-95 | 1.93 | 4" | 138 | 81 | 35 | 0 | 0 | 0 | 0 | 0 |
| Fantech HP190 | 60-85 | 2.01 | 4.5" | 123 | 89 | 45 | 0 | 0 | 0 | 0 | 0 |
| Fantech HP220 | 85-152 | 2.46 | 6" | 260 | 193 | 58 | 15 | 0 | 0 | 0 | 0 |
| Fantech HP190SL | 140 | 2.2 | 4" | 133 | 103 | 76 | 27 | 0 | 0 | 0 | 0 |
| RadonAway GP201 | 40-60 | 2.0 | 3" | 0 | 82 | 58 | 5 | 0 | 0 | 0 | 0 |
| RadonAway GP301 | 55-90 | 2.6 | 3" | 0 | 92 | 77 | 45 | 10 | 0 | 0 | 0 |
| RadonAway GP501 | 70-140 | 4.2 | 3" | 0 | 95 | 87 | 80 | 70 | 57 | 30 | 5 |
| RadonAway RP145 | 37-71 | 2.0 | 4" | 132 | 94 | 55 | 11 | 0 | 0 | 0 | 0 |
| RadonAWay XP151 | 45-60 | 1.3 | 4" | 140 | 78 | 10 | 0 | 0 | 0 | 0 | 0 |
| RadonAway RP265 | 86-140 | 2.5 | 6" | 260 | 207 | 139 | 57 | 0 | 0 | 0 | 0 |
| RadonAway XP201 | 45-66 | 1.9 | 4" | 110 | 74 | 38 | 20 | 0 | 0 | 0 | 0 |
| Suncourt TF104W | 40-60 | 1.5 | 4" | 145 | 90 | 35 | 0 | 0 | 0 | 0 | 0 |
| RadonAway RP140 | 14-20 | .8 | 4" | 68 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RadonAway XR261 | 65-105 | 1.8 | 6" | 165 | 75 | 30 | 0 | 0 | 0 | 0 | 0 |
| RadonAway GP500 | 70-130 | 4.3 | 3" | 0 | 88 | 80 | 74 | 65 | 54 | 28 | 14 |
Radon Fan Replacement Guide
| Originally Installed Fan | RadonAway Replacement |
|---|---|
| Fantech | |
| R100, F100, FR100, HP2133 | RP 140* |
| R150, F150, FR150 | XR261 or RP260 |
| R160, F160, FR160 | RP260 or RP265 |
| R175, F175, FR175 | RP265 |
| HP190, HP2190 | RP145 |
| HP190SL | SF180 |
| HP220 | RP265 |
| AMG | |
| Maverick | RP145, XP151 or XP201 |
| Hawk | RP260 or XR261 |
| Prowler | GP301 |
| Legend | RP265 |
| Eagle | GP401 |
| Goliath | RP260 or GP501** |
| Force | RP260 or GP501** |
| Kanalflakt / FanAmerica | |
| T1 Turbo 5 (Fiberglass) | XP201* or XP151* |
| T2 Turbo 6 (Fiberglass) | XR261 or RP260 |
| K4 (Metal Kanalflakt) | RP140* |
| K4XL (Metal Kanalflakt) | XP201* or XP151* |
| K6 (Metal Kanalflakt) | XR261 or RP260 |
| Rosenberg | |
| R100 | RP140* |
| R150 | XR261 or RP260 |
* Slightly different duct diameter requires different flexible couplings.
** Depends on site needs: airflow vs. static pressure